Cleaning, Care & Maintenance; Circuit Diagram - Eurofred VRX Serie Manual De Instrucciones

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

CLEANING, CARE & MAINTENANCE
Routine Maintenance
Switch off and disconnect from the power supply before cleaning.
Clean the enclosure and interior of the appliance as often as possible.
Wipe the unit with moist cloth. Never allow the switch, control panel, cable or plug to get wet.
Do not use abrasive cleaning agents. These can leave harmful residues. Use only mild soapy water.
Ensure that no cleaning water penetrates into the electrical components.
Must not be cleaned by a water jet.
Always wipe dry after cleaning with soft cloth.
Take care when cleaning the rear of the appliance.
An agent or qualifi ed technician must carry out repairs if required.
If the appliance is to be left inactive for long periods, unplug the appliance after having turned the switch to OFF position,
empty the refrigerating compartment and clean thoroughly.
Special Maintenance
The instructions given in the following paragraph are for SKILLED PERSON.
OPERA
Periodic Operations
Periodically clean the condenser using suitable tools ( vacuum cleaner or soft brushes)
Check that the electrical connections are not loose.
Check that the thermostat and the sensor are in proper working order.
Recommend that an agent or qualifi ed technician clean the condenser.

CIRCUIT DIAGRAM

P1
POWER PLUG
S1
MAIN SWITCH
TH1
HEATER SWITCH
C1
COMPRESSOR
QF1
OVERLOAD
R1
RELAY
F1
CONDENSER FAN
SQ1
TEMPERATURE PROBE