Installation Instructions - Osmofilter LITEL 100 J-100 Manual De Usuario

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

USER'S MANUAL
8. INSTALLATION INSTRUCTION
INSTALLATION PRECAUTIONS
NOTES:
The water purifier must be installed by professionals
from local service station. Unprofessional installation
may cause leakage of water or electricity and outbreak
of fire which will damage your property safety. In order to
ensure the normal operation of products, please choose
professionals from local service station to conduct the
installation.
Avoid direct
Non-special knife
sunlight
cutting is prohibited
Identify the source of water. The product must use the
municipal tap water or water that meets the GB5749
standards.
Confirm the water pressure of the inlet. The water
pressure range is from 0.1 MPa to 0.4 MPa. If the
water pressure above/below this pressure, you must
install a pressure-relief/pressurization device.
Confirm the ambient temperature of installation. The
product must be used in the environment whose
temperature is between 4-38
the product in the environment where the temperatu-
re may be higher than 40
The temperature of water must not higher than 40
either.
Choose the location of installation carefully. Install the
product near to cabinets or balconies or other water
inlet. It is prohibited to install the product under direct
sunlight or rainwater.
Pay attention to check whether the water purifier pipe
is proper or aging.
Pay attention to ensure that the PE pipe is inserted at
a depth of 15-17 mm. Measure the PE pipe before
installation and insert it into the machine after
marking the PE pipe. The insertion depth should
reach the position of the black point.
Check the TDS value of the outlet water.
Inform users of the precautions for daily use and
maintenance.
Do not forget to check the leakproofness of the
three-way ball valve, ensure that there is no seepage
or leakage of water.
Do not side lay, lay down or inverted product.
Do not use filter which has not been flushed (filter
must be flushed for 10-20 minutes).
Do not cut the PE pipe with non-special knife or other
tools.
PE pipe bending
is prohibited
. Please do not install
.
Do not install the product in the environment where
the temperature may be lower than 0
temperature of water must not lower than 0
A 115V fixed power socket is required within 1.5
meters of the machine. Please ensure that the power
socket and adapter are located in the indoor dry place
to prevent moisture from affecting the product.
Do not only replace the joint jaw when the joint is
leaking, the whole joint must be replaced.
Do not miss any detents.
Do not bend the pipe.
Do not insert waste water pipe into the user's sewer at
will. The drain pipe must be fixed with a tie.
10
EN
. The
either.

Capítulos

Tabla de contenido
loading

Tabla de contenido