INSTRUCTION MANUAL (Translation from the original Spanish)
A
Warning! Observe limitations of use.
B
The name plate voltage must be the same as the
mains voltage.
C
Connect the pump to the mains via an omnipolar
switch with at least a 3mm opening between contacts.
D
Install a high-sensitivity differential switch (0.03A)
as extra protection against lethal electric shocks.
E
Connect the pump to the ground.
F
Use
pump
only
indicated on the name plate.
G
Remember to prime pump.
H
Check for motor self-ventilation.
Contents
Safety precautions .................................................... 9

1. General information ............................................. 9

2. Handling ............................................................. 10
3. Installation ......................................................... 10
3.1. Fixing ............................................................ 10
3.2. Suction pipe assembly ................................. 10
3.3. Discharge pipe assembly ............................. 10
3.4. Electrical connection..................................... 10
3.5. Pre-start checks ............................................ 10
4. Starting .............................................................. 10
4.1. Starting-up the group .................................... 10
4.2. Lack of water fault and retries ......................10
4.3. Minimum flow ................................................ 10
5. Maintenance ...................................................... 10
6. Disposing of the product .................................... 11
7. Nameplate ......................................................... 11
8. Technical data ................................................... 11
9. Possible faults, causes and solutions ................ 11
10. List of main components .................................... 36
11. Illustrations......................................................... 37
Safety precautions
This symbol
following words "Danger" or "Warning" indicates the
risk level deriving from failure to observe the
prescribed safety precautions:
DANGER
Warns that failure to observe
the pre cautions involves a risk
risk of
of electric shock.
electric
shock
DANGER
Warns that failure to observe
the pre cautions involves a risk
of damage to persons and/or
things.
WARNING
Warns that failure to observe
the pre cautions involves the
risk of damaging the pump
and/or the facility
Damage prevention and safety instructions
(See figure 7)
within
performance
limits
together with one of the
I
This apparatus may be used by children older
than 8 and persons with reduced physical,
sensory
or
mental
experience and knowledge, if they are supervised
or receive adequate training on the safe use of
the apparatus and understand the dangers.
Children should not be allowed to play with the
apparatus.
Children should not perform the ordinary cleaning
and maintenance tasks without supervision.
J
Be careful with hazardous liquids and
environments.
K
Caution! Look out for accidental leaks.
Do not expose pump to bad weather.
L
Caution! Avoid icing.
Cut out power supply before servicing pump.
1. GENERAL INFORMATION
Please observe the following instructions to achieve
the best pump performance possible and a trouble
free installation.
Read these instructions before installing the
pump. Save them for future reference.
These are multistage centrifugal pumps having
more than one impeller assembled in-line. The
same flow passes through each impeller but the
pressure increases each time, i.e. more impellers,
more pressure.
By using a foot valve on the suction pipe the pump
will rapidly self-prime when operated.
These pumps are designed to operate with clean
water, free from particles in suspension and with a
maximum temperature of 40ºC.
KIT02 is completely silent and are designed to
provide an automatic supply of clean water to one
or two dwellings.
It is a compact kit comprising a check valve,
electronic circuit and reset button.
It is designed to maintain constant pressure. It does
not permit the pump to operate without water and
avoids water hammering. It requires no preloading of
air or adjustment. It has a water reserve to prevent
the unit from being started by a dripping tap.
If water consumption is more than 1 l/min the pump
will operate continuously.
When the pump reaches maximum pressure the
unit automatically switches the pump off. Unit
selection must take into account the fact that the
differential must be over 0.7 bars.
Correct pump operation is assured providing
the instructions on electrical connection,
installation and use are strictly adhered to.
Failure to adhere to the instructions can
result in premature failure of the pump and
voiding of the warranty.