Malfunctions

Other malfunctions

Malfunctions
No response
Faulty com-
to operation at
munication
the mixer tap
to the mixer
(blue LED)
tap
Faulty images
Faulty
on the display
communi-
cation to the
display
Mixer tap is dripping from the
soda outlet
Only CO₂ is coming out of the
soda outlet
Spray from the soda tap spitting/
uneven soda spray
The soda spray is too weak
The volumes dispensed do not
match the pre-selected volumes
56
Possible causes
- Faulty operation
- Incorrect signal
- Faulty operation
- Incorrect signal
Air or CO₂ in the system
because:
- Filter not inserted
correctly
- Angle valve closed
- Water supply disrupted
- Filter reinstalled
- CO₂ cylinder empty
Malfunction correction
- Unplug the signal cable from the
cooling and carbonisation unit and
plug it in again
- Disconnect the power supply and
reconnect it
- Calibrate the system (see p. 45 + 51)
- Check the soda pipe
- Set the soda pipe length correctly
(contact Customer Service)
- Evacuate air from the system (see p. 57)
Check that the filter has been installed
correctly (see p. 50)
- Check water inlet
- Evacuate air from the system (see p. 57)
- Change CO₂ cylinder
- Calibrate the system (see p. 45 + 51)