EUCHNER NP Serie Manual De Instrucciones página 6

Ocultar thumbs Ver también para NP Serie:
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Operating Instructions
Safety Switch NP...
Switching element
Switching contacts
618
1 NC contact
628
1 NC + 1 NO contact
638
2 NC contacts
648
2 NC + 1 NO contact
Fig. 4: Switching elements and switching functions
NP1-...AS
NP1-...AB
Fig. 5: Dimension drawing for NP...
Hinged actuator P-OU/P-OUN
35
Fig. 6: Minimum door radii
2083684_09-04_21.mx.indb 6
2083684_09-04_21.mx.indb 6
Guard
Guard
closed
open
v
h
21
22
21
22
21
22
21
22
13
14
13
14
21
22
21
22
11
12
11
12
4
31
32
31
32
21
22
21
22
13
14
13
14
Necessary minimum travel + permissible overtravel
Approach direction
Horizontal (h)
Vertical (v)
Order actuator separately
M4 (2x)
M20 x 1,5
M20 x 1,5
Actuator
Actuator P-G...
Actuator P-W...
Hinged actuator P-OU...
20
Hinged actuator P-LR...
Terminal assignment
with plug connector SR6
618
628
21
22
21
22
1
2
1
2
3
4
13
14
Terminal assignment
with plug connector M12
3
638
2
21
22
3
11
12
1
1
Standard actuator
Overtravel actuator
28 + 2
28 + 7
29.5 + 7
29.5 + 1.5
Only with adapter NP-K
NP.-... with adapter NP-K
NP2-... with plug connector SR6
Door radius, min.
[mm]
1,000
1,000
90
100
6
Connector illustration
Plug connector SR6
View of safety switch connection side
638
21
22
1
2
3
4
11
12
Connector illustration
Plug connector M12
View of safety switch connection side
3
2
4
4
2
1
NP3-... with plug connector SM4 (M12)
Built-in connector
not aligned
M12x1
Hinged actuator P-LR/P-LRN
638
21
22
3
4
11
12
1
2
11.05.2021 13:37:01
11.05.2021 13:37:01
Tabla de contenido
loading

Este manual también es adecuado para:

Np1 serieNp2 serieNp3 serieNp1-618as-m083685

Tabla de contenido