• Load curve Lead:
The GYSflash 6.24 PL uses a 7-step lead charging curve that guarantees the optimal performance of your lead battery.
U
I
CHARGE
1
Step
: Analysis
Analysis of the battery condition (charge level,polarity rever-
sal, incorrect battery connected...)
2
Step
: Recovery (3 A)
Recovering damaged elements due to a prolonged deep
discharge.
3
Step
: Test
Sulfated battery test
4
Step
: Desulfation (31.6 V)
Battery desulfation algorithm.
• Lithium charging curve :
The GYSflash 6.24 PL uses an advanced 8-step Lithium charging curve that guarantees the optimal performance of your lithium
battery.
U
I
CHARGE
OK
10
1
2
Analysis
Recovery
<1s
Max 8h
OK
1
2
3
Analysis
Recovery
Charging
< 1s
Max 5 min
Max 25 h
GYSFLASH 6.24 PL
3
4
Test
Desulfation
Charge
Max 12h
Max 20h
<1s
5
Step
: Charge (6 A)
Maximum current fast charge to reach an 80% charge level.
6
Step
: Absorption (29.2 V)
Constant voltage charge to reach 100% charge level.
7
Step
: Load retention (27.2 V)
Maintain the battery charge level at its maximum.
4
5
Absorption
Test
Complement
Max 20 h
3 min
Max 10 h
5
6
Load retention
Absorption
Max 8h
No limit
6
7
Equalizing Battery System
Equalization /
Charge retention
balancing
Max 2 h
(maintenance every 10 days)
EN
7
8
No limit