SAFETY INSTRUCTIONS/WARNING
This recess kit is to only be used with the AeraMax Professional AM II Air Purifier. It is not intended for use with any other unit.
WARNING: Follow the instructions in this manual to reduce the risk of electric shock, short circuit, and/or fire:
• WARNING: To avoid the risk of electrocution, confirm the electrical supply has been disconnected or switched off before beginning any work.
Confirm no electrical wiring, utility pipes, duct work, or any other obstruction is located directly behind the installation/drilling area.
• Deviation from the assembly instructions may result in a risk of fire or electric shock.
• Please read manual in its entirety before attempting an installation.
• Save manual for future use.
• Once installed as a recessed unit. This same unit cannot be converted back to wall mounted or stand unit.
• Use this kit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer.
• Use only the electrical power (voltage and frequency) specified for the model air purifier being installed. Verify voltage with sticker on
electrical cover on unit.
• Do not use if internal power cords are damaged.
• Do not handle/install with wet hands.
• Before servicing or cleaning the air purifier, switch power off at service panel. Lock service panel, or affix a warning tag, to prevent power
from being switched back on accidentally.
• Do not obstruct air inlet or air outlet of the air purifier.
• Equipment (switch), having a contact separation in all poles that provides full disconnection under overvoltage category III conditions, must
be incorporated in the fixed wiring in accordance with applicable wiring rules.
• Unit utilizing this recess kit must be installed by a professional technical support or customer service.
• All permanent wiring must be installed per local wiring rules.
1
2
3
ITEMS IN KIT
A
380mm
B
C
Recess Pan
Wall Template
DRAWN BY:
B. Ho man
Please note: There are many types of walls, some of which will require specific hardware and installation methods. Please contact a professional contractor/builder for consultation.
CHECKED BY:
Dimensions for
Recess Kit Template
APPROVED BY:
2
1:5
SCALE:
DATE:
3/19/2008
TOLERANCES
F
UNLESS OTHERWISE SPECIFIED
MATERIAL:
GB/T 1804
Edges of working parts
-0.4
+0.4
PART NO:
Weight:
Recess Kit Template
Recess Kit for AeraMax PRO AM II
4
Power Cord
(4) Wood Screws
(4) Main Unit to Recess
Pan Screws
SHEET
1 / 1
ORIGINAL SIZE:
REV:
A4
Rev
ENGLISH
TOOLS RECOMMENDED FOR INSTALLATION
• Stud Finder
• Level
• Tape or pins to hold template
• Drywall / Jab Saw
INSTALLATION GUIDELINES
BEFORE STARTING, TURN OFF POWER AT MAIN CIRCUIT PANEL!
IMPORTANT: When the AM II Air Purifier is hardwired, the power switch on the machine no longer operates. Equipment (switch), having
a contact separation in all poles that provides full disconnection under overvoltage category III conditions, must be incorporated in the
fixed wiring in accordance with applicable wiring rules.
1
20cm min From
30.5cm min From
Note: Unit should not be placed on exterior wall.
4
Main Unit
The recess pan contains a cutout for a 12.7mm trade
size conduit connection.
(Sold separately)
Note: All permanent wiring is to be employed as
required by local codes.
• Screw Driver #2 Philips
• Electric drill, drill bits (#2 Philips driver)
• Electrical cutters / strippers
• Wire nuts
2
41cm
Ceiling
Center to Center
Flooring
Find stud locations – must be 41cm on center minimum.
5
Cut Out
Hole
Following your local electrical codes, provide
an electrical supply to the conduit cutout of
the recess pan. This will connect with the main
unit in later steps.
1
2
3
4
A
3
380mm
B
C
Place the provided wall template on the wall between
studs and cut a hole following the outline on
the template.
DRAWN BY:
B. Ho man
CHECKED BY:
Dimensions for
Recess Kit Template
APPROVED BY:
1:5
1 / 1
SCALE:
DATE:
3/19/2008
SHEET
TOLERANCES
F
UNLESS OTHERWISE SPECIFIED
ORIGINAL SIZE:
REV:
MATERIAL:
A4
Rev
GB/T 1804
Edges of working parts
6
-0.4
+0.4
PART NO:
Weight:
Recess Kit Template
Phase:
Part Phase
First Angle
Hole for
Conduit
Place the recess pan in the wall cutout with the hole
for the conduit at the bottom.
3