PROBLEM OR CONCERN
Unit will not stop when trig-
ger is released
Wand - Attaching
Wand - Removing
Circuit breaker trips or Fuse
blown in Fuse Box
GFCI Plug installation
GFCI Plug malfunction
POSSIBLE CAUSE
Garden Hose is kinked or
leaking water
Wand is malfunctioning
Gun is not operating properly
Circuit overload
Extension cord too long or wire
size too small
Nozzle partially blocked
Excessive pressure
SOLUTION
Make sure the Garden Hose is laid out flat and
there are no kinks in it. The hose should not be
wrapped on a storage wheel. Make sure the
faucet is open all the way and there is a full
volume of water reaching the unit.
Test all wands to ensure that one is not
functioning.
Remove Wand from the Gun and squeeze trigger to
ensure that the water is coming out of the front of the
Gun at a rate equal to the Garden Hose.
To attach the Wand apply some moderate
downward pressure force on the Wand (In the di-
rection of the trigger) while simultaneously twisting
the wand a 1/4 of a turn counterclockwise. (It may
help if you set the gun vertically on a flat surface
with the wand pointing upwards). The two tabs on
the end of the Wand must slide all the way in before
the Wand will twist and lock. If this does not work
remove the o-ring from the end of the wand and
attach it without the o-ring. If the wand attaches,
you will need to replace the o-ring.
or order a replacement directly online at www.
hdpowerwasher.com
Release the back pressure in the Gun/Hose. Re-
move the Garden Hose from the unit and squee-
ze the trigger of the Gun. Apply some moderate
downward pressure force on the Wand (In the
direction of the trigger) while simultaneously
twisting the wand a 1/4 of a turn clockwise. (It
may help if you set the gun vertically on a flat
surface with the Wand pointing upwards). For
additional assistance you can email us at
Check that the circuit is rated at 15 amps or
greater. Make sure the unit plugged into a de-
dicated circuit.
Used proper extension cord as recommended
in Owner's Manual.
Clean Nozzle as instructed in section 5.2.
Clean Nozzle as instructed in section 5.2
For GFCI reset procedures see owner's manual
section 3.3. For instructions regarding the GFCI
Plug installation or malfunction please email us
directly at: