CHRONOGRAMS
Ambient
temperature
Chronogram.
Indication of
temperatures
Programmed in
1
2
time periods
MANUAL OPERATION (THERMOSTAT)
With the apparatus in normal mode, press the
will operate as a normal thermostat, without any time programming, only taking into
account the temperature. The desired temperature is selected simply by pressing
the
or
button until it is displayed. The unit will commence operating as a
thermostat ten seconds after the final temperature modification and display the
ambient temperature and the word MANUAL on the screen.
To return to the timer-thermostat mode, press the
TEMPORARY MANUAL MODE
This mode is used to manually modify the temperatures corresponding to the
consecutive time periods with the same control temperature. When the programme
changes the control temperature type, it will return to the established programme.
To select this when in START mode, press the
time period control temperature will be displayed. If the
again, the control temperature for the consecutive time periods will be modified,
with the unit entering TEMPORARY MANUAL.
The control temperature symbols will disappear from the display while the
TEMPORARY MANUAL mode is activated and the word MANUAL will appear
flashing.
To exit this mode before completion, turn the programming wheel from START to
any other mode and it will return to START, or the
Example:
The programmed control temperature is to be temporarily modified to 22ºC, with
the MIRUS programmed with the following parameters:
• Control temperatures: Savings (
• On Tuesday at 18:24.
• With the following programme for this day:
- Savings
: 00:00 to 09:00, 13:30 to 20:00 and 22:30 to 00:00h.
- Comfort
: De 09:00h a 13:30h y de 20:00h a 22:30.
This is achieved in START mode by pressing the
control temperature is displayed for the current time period. the
pressed again to change the temperature value to 22 ºC.
From this moment, the MIRUS will regulate heating On/Off until 22ºC is reached,
during the time that the control temperature is consecutively programmed (the one
just modified) until 20:00 when the control temperature mode is changed in the
programming to Comfort (
).
Before applying the TEMPORARY MANUAL mode, the display will show the
configured chronogram:
1
2
Control temperature symbol for the
current time (flashing)
When the TEMPORARY MANUAL mode is activated the display will show the
following:
1
2
Boiler operation
indicator
Manual operation
indicator
3
4
5
6
7
Day of the
week
Current time
button and the timer-thermostat
button again.
or
button and the current
or
button is pressed
button can be pressed twice.
) at 17ºC and Comfort (
) at 20ºC.
or
button so that the
or
3
4
5
6
7
Temporary manual
operation indicator
(flashing)
3
4
5
6
7
No control
temperature symbol
OFF OPERATION
If the equipment is switched On, pressing the
heating will not be switched On, the temperatures cannot be modified and the
screen will be OFF. This mode, the unit measures the ambient temperature, but will
not perform any of its functions, except if the temperature falls below +5ºC, at
which point it will activate the de-icing programme and will switch the heating On to
prevent freezing.
This mode is exited by pressing the
RESET
The RESET is pressed in order to reset the timer-thermostat. Then all the
parameters have to be reprogrammed. In any case, the last weekly programme
entered prior to the reset will remain in memory.

TECHNICAL SPECIFICATIONS

Power supply:
Switching power:
Contact:
Battery duration:
Temperature measurement precision:
Temperature update:
Resolution:
LCD measurement range::
Action type:
Number of programmes:
Minimum programmable times:
Operational precision:
Output relay update:
Control temperature regulation:
Regulation type:
Operating temperature:
Transport and storage temperature:
Protection class:
Protection type:
Contamination situation:
Transient pulse voltage:
Ball test temperature:
button is
Connection
WARNING: Contactors must be employed if the maximum load current
exceeds the switching current.
DIMENSIONS
30
02.01/2012
button will switch it Off, the
button again.
Two LR6/AA, 1. Alkaline batteries (not
included)
µ 10 (3) A 250 Vac
AgNi switched, 90/10
Approximately one year
± 0.5°C
Every 60 seconds.
0.1°C.
0ºC to 50ºC
1B, 1S, 1T and 1U
7 (one for each day of the week)
30-minute periods
≤ ±1.2 sec/24 h at 23ºC
Every 60 seconds
Savings
Comfort
Anti-freezing: 5ºC
Manual: +5ºC to +35ºC
ON-OFF with 0.3ºC hysteresis
0ºC to +50ºC
-10ºC to +60ºC
II according to EN 60335 with correct
installation
IP40 according to EN 60529 with
correct installation
Normal
2.5 kV
75ºC (21.2.5); 105ºC (21.2.6)
Screw terminals for wires having a
maximum 2.5 mm² section
138
ORBIS TECNOLOGÍA ELÉCTRICA, S.A.
Lérida, 61
Telephone:+ 34 91 5672277;
E-mail: info@ orbis.es
http://www.orbis.es
: +5ºC to +25ºC