Orbis MIRUS Guia De Inicio Rapido página 5

Cronotermostato
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

RESET
COMFORT
TEMPERATURE
SELECTION
SAVINGS
TEMPERATURE
SELECTION
ON / OFF
SET DAY / TIME
DESCRIPTION
The MIRUS timer-thermostat is an electronic ambient thermostat that is easy to
use. It enables different temperatures to be assigned to various time periods.
Main Specifications:
• Seven independent configurable programmes (one for each day of the week)
• Large backlit display
• Easy to programme off the base
• Heating control
• Two adjustable temperature levels: Comfort
• Temperature adjustment from +5ºC to +35ºC
• Temperature measurement and adjustment resolution: 0.1ºC.
• Anti-icing temperature set at +5ºC (to prevent freezing).
• Daily programmes: Configurable periods of 30 minutes.
INSTALLATION:
WARNING. The installation and assembly of the electrical apparatus shall be
undertaken by an authorised installer.
ALL POWER SHALL BE SWITCHED OFF BEFORE PROCEEDING WITH THE INSTALLATION.
THE POWER SHALL BE SWITCHED BACK ON ONLY WHEN THE EQUIPMENT IS FULLY
INSTALLED.
The apparatus is internally protected against interference.
INSTALLATION:
This is an electronic control device for independent installation on a wall or in a
mechanism box.
It is recommended that the apparatus be installed at a minimum height of 1.5
metres. The timer-thermostat installation shall be independent so that it is free from
obstacles and not affected by other devices or heat sources (sun, radiators, and
windows etc.)
When fixing the apparatus to the wall and in order to change the batteries, the
device mounting base must be released by applying pressure with a flat
screwdriver to the tab on the left side of the apparatus.
Fix the installation plate to the wall or mechanism box with the included crews.
CONNECTION:
Remove the terminal cover using a screwdriver and connect it according to the
following diagram:
HEATING
To control an installation via the meters, it is recommended that a suitable
capacitor be connected to its winding (0.1 μF 275 Vac).
TIMER-THERMOSTAT
MIRUS
INSTALLATION PLATE
PROGRAMMING
WHEEL
INCREASE /
MOVE FORWARD
MANUAL
OPERATION
DECREASE /
MOVE BACK
and Savings
.
INSTALLATION PLATE
1
2
3
INSERTING AND CHANGING BATTERIES:
The apparatus is fed by two LR6 (AA) 1.5 V alkaline batteries (not included). The
polarity indicated on the battery compartment must be respected. The batteries last
approximately one year.
When batteries are inserted for the first time, the screen is switched on and all the
display segments are shown and, after a few seconds, the timer-thermostat is
ready for operation.
When the MIRUS batteries have little power left and require changing, The "Lo"
symbol is displayed at the bottom of the screen.
In order not to lose the current time, day of the week and temperatures
configuration, the battery change operation should be accomplished within fifteen
seconds. In any case, the fixed programming remains stored.
All used batteries shall be disposed of in a correct fashion. Respect the
environment.
SCREEN BACKLIGHTING
When any button is pressed on the MIRUS, the temporary backlighting comes on
to illuminate the display in order to easily programme the device.
SETTING THE TIME
The programming wheel is set to START and the button
of the week digit begins to flash. The
corresponding day, the
button is pressed again to repeat the operation for the
hours and minutes in this order. Five seconds later automatic mode is entered with
the current time now set.
AUTOMATIC OPERATION (TIMER-THERMOSTAT)
When the programming wheel is set to the START position, the MIRUS will switch
the heating ON or OFF according to the current day programming. The TIMER will
show this programming in the display.
CONTROL TEMPERATURES
The factory-set temperatures are:
Savings
: 17 ºC
Comfort
: 20 ºC
These temperature values can be modified in START mode by pressing the button
corresponding to the temperature to be configured (Comfort
using the
or
button to change the value.
In order to determine the programmed type and temperature in the MIRUS at the
current time when in START mode, press either the
PRESET PROGRAMMES
The MIRUS Timer-Thermostat is factory-set with the following programming
Savings
: 00:00 to 06:00, 09:00 to 12:00, 15:00 to 17:00 and 22:00 to 00:00.
Comfort
: 06:00 to 09:00 to 12:00 to 15:00 and 17:00 to 22:00.
Saturdays and Sundays:
Savings
: 00:00 to 08:00 and 22:00 to 00:00.
Comfort
: 08:00 to 22:00.
MODIFYING PROGRAMMES
The programming wheel is set to the day to be programmed (for example, Monday
– 1, Tuesday – 2 etc.).
The temperature type is programmed in 30-minute periods beginning at 00:00. The
temperature type is defined by pressing the button corresponding to the desired
temperature (Comfort:
, Savings:
the following time period is selected. The
the time periods leaving the already assigned temperature.
In order to determine the programmed temperature, the display will show the start
time and the defined control temperature symbol will flash in the programme being
modified.
If there is no flashing symbol, it means that the time period being programmed the
timer-thermostat is Off, however, the anti-icing mode remains activated.
The programmed can be stored by moving the wheel to another day or to the
START position.
If, during programming, one minute passes without any button being pressed, the
screen will display "Err" and the relay will de-energise until a button is pressed in
order to continue with the programming operation.
INSTALLATION PLATE
is pressed and the day
or
button is used to select the
or Savings
or
button.
, Off:
) . When the temperature is defined,
or
button is used to move through
)