Comelit 20005000 Manual Tecnico página 5

Art. 20005000 allows monitors and home automation system managers for the ViP system to be used in
Simplebus2 audio/video setups. The ViP monitors/system managers can be used to receive calls from the
external unit and send commands to Simplebus2 devices (self-ignition, call to main/secondary switchboard,
intercom call, actuator control, camera module control, etc.); the device also offers integration with the
SimpleHome home automation system and video entry phone call forwarding via the Comelit App.
Equipped with 1 Comelit PoE Ethernet port for connection to the ViP monitor and terminals for connection to
the Simplebus2 system.
Fig. 1
In relation to the SImplebus2 section of the system, the device should be considered as a separately powered
Simplebus monitor.
1.
Power LED
2.
Connection terminals
| L | L | Simplebus2 Data line
| + | - | Power supply Positive / Negative 12/56 VDC (supplied by external power supply unit)
Make sure the power supply unit earthing is connected.
3.
CV5 Jumper for video closure (Factory setting: closed)
Jumper closed if there is no Simplebus monitor on the line
Jumper open if there are successive Simplebus monitors connected in cascade on the line
4.
DIP-Switches Selectors used to set the Simplebus address
Every time an address is changed the device must be restarted!
5.
DIP-Switches Selectors used to implement reset procedures (See "Reset procedures")
6.
Indicator LED
Flashing slowly
Steadily lit
System starting up
Simplebus line present
/ updating
System ready
7.
CV1 (Factory setting: closed)
Jumper open if at least one Simplebus monitor with the same address is on the line
8.
LAN port - Comelit PoE Output - IP address Factory setting: DHCP
Only connect to the router or PC using red Comelit cable 1449
9.
Indicator LED
Red
Green
Steadily lit
Normal operation
Steadily lit
Flashing
See "Reset procedures"
Flashing
Technical specifications
Power supply voltage
12 ÷ 56 VDC
Max. absorption (mA)
1100 ÷ 450 (in relation to the power supply voltage)
200mA @12V
Max. current delivery
300mA @24V
Operating temperature
-5 ÷ 50°C
Operating humidity
5 ÷ 95%
Dimensions
90 x 70 x 59 mm (4 DIN modules)
Functions
Art. 20005000 allows use of the Comelit video entry system functions, with the exception of: Call divert / Range
/ Selective intercom / Alarm.
CFP (Floor door call): If there are both Simplebus monitors and ViP monitors in the apartment, connect the
CFP to just one Simplebus monitor to receive the call on all monitors.
8
Flashing quickly
Simplebus line missing
/ short-circuited
Yellow
Normal operation
Ethernet connection
present
See "Reset procedures"
400mA @48V
400mA @56V
ViP monitor addressing
The address of a monitor in a Simplebus system is the address of the apartment preceded by SBVIP
Examples
Apartment 1
Apartment 2
If the ViP monitor keypad does not allow the entry of alphanumeric codes, proceed using ViP Manager
software.
Addressing Simplebus devices
To allow the ViP monitor to communicate with Simplebus devices connected to the system, addresses must be
assigned, in the ViP monitor directories, in accordance with the table:
External unit
SBEXT001
(Function: Self-activation)
Secondary switchboard
(Function: call to secondary
SBCPS007
switchboard)
Main switchboard
SBCPS008
(Function: call to main switchboard)
Caretaker door-entry phone
(Function: call to caretaker door-entry
SBCPS009
phone)
Internal unit
SBINTxxx
(Function: general intercom call)
Reset procedures
Reboot with predetermined network settings
This procedure allows you restart the device with the
default network parameter settings, while keeping the
other settings unchanged.
√ DIP-switches in the default positions (OFF)
1. Switch off the power supply to the device
2. Set DIP1 to ON
3. Power on the device
4. Wait 20-40 sec. until the LEDs start flashing slowly
and alternately (1 sec. red / 1 sec. green)
5. Return the DIP-Switche to OFF
›› The green LED will flash for 5 sec..
›› The device will start with the default network settings.
6. At the next restart, the device will recover the
saved settings.
Simplebus address
ViP address
001
SBVIP001
029
SBVIP029
Generic actuator
SBACT255
(Function: generic actuator control)
Coded actuator xxx
SBACTxxx
(Function: coded actuator control)
Generic camera module
(Function: generic call module
SBCAM255
control)
Addressed camera module xxx
(Function: addressed camera
SBCAMxxx
module control)
Restoring factory settings
This procedure allows you to restore all the factory
parameter settings and to delete all the device
configurations.
√ DIP-switches in the default positions (OFF)
1. Switch off the power supply to the device
2. Set all the DIP-switches to ON
3. Power on the device
4. Wait 20-40 sec. until the LEDs start flashing rapidly
and alternately (0.1 sec. red / 0.1 sec. green)
5. Return all the DIP-Switches to OFF
›› The red LED will flash for 5 sec.
›› The device will reset all parameters to the factory
settings and restart in the normal way.
9
loading