5
5.1
Check fuses on the circuit boards.
Getting Started
Check input terminals on board for correct input voltage. Refer to the circuit board
diagram.
Installation
5.2
Check pump(s) output terminals for loose screws and disconnected wires.
Set Up & Operation
Check for proper voltage across motor windings.
Check for obstruction in pump head(s).
Maintenance &
Accessories
5.3
Check the voltage to the system.
TROUBLESHOOTING
Check for open wires between the probe and the connections to the circuit board barrier.
Contacting SEKO
5.4
Check the voltage to the system.
Check pump operation for proper speed
5.5
Check roller block for binding.
Check for lubrication on squeeze tube.
5.6
Check pickup line for any holes or air leaks.
Check squeeze tubing in pump for any cracks or pin holes.
Check tubing for deterioration.
TWINDOSE 20
TROUBLESHOOTING
POWER LIGHT DOES NOT ILLUMINATE:
PUMP(S) WILL NOT ACTIVATE:
TOO MUCH DETERGENT:
TOO LITTLE DETERGENT:
PUMP RUNS TOO SLOWLY:
LOSS OF PUMPS PRIME:
Rev. 1.4