3.0 Installation

First remove the wallplate from the back of the unit.
From the top left hand corner of the wallplate, there must be
clearances of at least 15mm to the right, 15mm to the left, 30mm
above and 100mm below in order to mount the plug-in module.
Before mounting the unit ensure the 4 DIL switches on the
rear of the unit have been moved to the required settings (see
below). Factory preset is 7-day, with Optimum Start and Chrono-
proportional control OFF.

3.1 DIL Switch Settings

All models
1
w
5/2 day programming
2
w
Optimum start contoller enabled
3
w
Chrono-proportional control
TP7000, M, & RF models with 3/6 cycles per hour option
4
w
Chrono-proportional, 6 cycles / hour
NOTE
Use Chrono 3 for high thermal inertia systems, e.g. fl oor standing cast iron
boilers.
Use Chrono 6 for low thermal inertia systems, e.g. low water content
boilers and combi boilers.
Danfoss Heating
7 day programming
Optimum start contoller disabled
On/Off control
Chrono-proportional, 3 cycles / hour
GB
F
D
ES
DK
NL
I
GR
PL
LT
CZ
HR
RO