Led Operation - Honeywell HVC20A1000 Manual De Instrucciones

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Installation Guide

LED Operation

During normal operation the LED will be off when the remote is idle. If the LED
remains off when a button is pressed then the battery has failed.
After a button press the LED will function as follows:
• Green when a button is pressed.
• Quickly flashing red when the battery needs to be replaced.
• Slowly flashing amber when the remote is disconnected from the system.
• The LED will be off when the remote is idle.
During wireless connection to the system the LED will function as follows:
• Solid green for 15 seconds: connected to the system.
• Solid red: the remote did not connect to the system.
Disconnect from RedLINK System
Press and hold the CONNECT button on the remote until the LED glows amber
(about 10 seconds) to disconnect from the RedLINK system.
If you replace a thermostat or Equipment Interface Module, disconnect the remote from the old device. Then follow the steps
on page 1 to re-connect the remote to the wireless network.
Setting up Ventilation and Filtration Boost at the Thermostat
Ventilation and Filtration Boost
Wire ventilator and choose the type of ventilation in Installer Set Up of the thermo-
stat. Filtration will be boosted with ventilation if the system is set up to run the fan
with ventilation.
Filtration Boost without a Ventilator
Choose passive ventilation (fan only) for the ventilation type in Installer Set Up of the
thermostat. When the remote button is pressed the equipment fan will circulate air
through the filter.
Operation
The Wireless Vent and Filter Boost Remote provides one-
touch control of the ventilation and filtration systems.
The remote has three buttons: 20, 40, and 60 minutes. The
ventilation and filtration can be temporarily boosted for 20, 40,
or 60 minutes, depending on the button pressed.
Pressing one of these buttons temporarily boosts the
ventilation and filtration for either the time on the button or the
current run time at the thermostat, whichever is greater. Vent
boost can be cancelled from the thermostat.
69-2677EFS—03