Notes:
Daisy chain connection is not available for full duplex.
●
With a distant unit, communication may fail to be maintained because of a GND potential
●
difference. In such a case, use the GND circuit in common, or use an RS isolator or the like
available on general market.
RS485 Terminals
Control data is transmitted and received to and from other peripherals.
Notes:
Two twisted pairs cable
●
Low impedance
●
Wire gauge size is thicker than AWG#22 (0.33 mm
●
Internal Diagram
●
<Full duplex>
Data Transmission
Data Reception
SETTING PROCEDURE
Hold down the SET button to open the SETUP menu.
When the SET button is pressed for each item, each setting can be made.
Setting can not be made if ON setting has been made for PASSWORD LOCK. Setting should
be carried out after PASSWORD LOCK has been canceled.
Refer to Page 29 in regard to the method of PASSWORD LOCK canceling.
To close the menu from Camera Setup buttons, select END.
●
If no operation is performed for 6 minutes, the menu becomes automatically closed.
●
14
)
2
<Half duplex>
T (B)
Data Transmission
T (A)
R (B)
Data Reception
R (A)
** WV-CZ352 SETUP **
CAMERA
PRESET POSITION
SPECIAL
COMMUNICATION
PASSWORD LOCK OFF
END
T (B)
T (A)
R (B)
R (A)