Optional Installation

For connection instructions, see the Basic Operation section.
USB Communication Port: This port connects your UPS system to a computer for
automatic file saves and unattended shutdown in the event of a power failure. This
connection is optional. The UPS system will work properly without this connection.
Tel/DSL Protection Jacks: These jacks stop surges on a phone or fax line. Connecting
your equipment to these jacks is optional. Your UPS system will work properly without
this connection.

Basic Operation

Note: individual models may vary from diagrams.
2
3
4
5
1
1
ON/OFF/TEST Button
• To turn the UPS system on: press and hold the ON/OFF/TEST Button for one
second.* If utility power is absent, pressing the button will cold-start the UPS
system (power it on and supply power from its batteries**).
• To turn the UPS system off: press and hold the ON/OFF/TEST Button for one
second.* The UPS system will be completely deactivated.
• To run a self-test: with your UPS system plugged in and turned ON, press and hold
the ON/OFF/TEST button for three seconds.
* The alarm will beep once briefly after one second has passed. **If fully charged.
CAUTION! To perform a self-test, you must hold the ON/OFF/TEST button
continuously for three seconds. If you release the button too early, you will
turn the UPS system OFF and cut power to connected equipment loads. To
ensure you hold the button for the correct length of time, do not release the
button until you hear the UPS system's audible alarm beep twice. The first
beep occurs after one second and indicates the UPS system will turn OFF if
the button is released.