Multi-Protocol Operation

Analog Operation
This decoder can also be operated on analog layouts or
areas of track that are analog. The decoder recognizes
alternating current or direct current voltage (AC/DC) and
automatically adapts to the analog track voltage. All func-
tions that were set under mfx or DCC for analog operation
are active (see Digital Operation).
Digital Operation
The mSD sound decoders are multi-protocol decoders.
These decoders can be used under the following digital
protocols: mfx, DCC, fx (MM).
The digital protocol with the most possibilities is the highest
order digital protocol. The sequence of digital protocols in
descending order is:
Priority 1: mfx
Priority 2: DCC
Priority 3: fx (MM)
Note: Digital protocols can influence each other. For trouble-
free operation, we recommend deactivating those digital
protocols not needed by using CV 50. Deactivate unneeded
digital protocols at this CV if your controller supports this
function.
If two or more digital protocols are recognized in the track,
the decoder automatically takes on the highest order digital
protocol, example: mfx/DCC; the decoder takes on the mfx
digital protocol (see previous table).
24
Note: Please note that not all functions are possible in all
digital protocols. Several settings for functions, which are
supposed to be active in analog operation, can be done
under mfx and DCC.
Braking / Signal Stopping Block (MM, fx, mfx)
The braking module essentially applies DC voltage to the
track. If the decoder recognizes a DC voltage of this kind in
the track, it brakes with the delay that has been set. If the
decoder recognizes a digital protocol again, it accelerates
at the speed that has been set.
If automatic recognition in braking areas is to be used, we
recommend shutting the DC operation off (see CV descrip-
tion).
mfx Protocol
Addresses
• No address is required; each decoder is given a one-
time, unique identifier (UID).
• The decoder automatically registers itself on a Central
Station or a Mobile Station with its UID.
Programming
• The characteristics can be programmed using the
graphic screen on the Central Station or also partially
with the Mobile Station.
• All of the Configuration Variables (CV) can be read and
programmed repeatedly.
• The programming can be done either on the main track or
the programming track.
• The default settings (factory settings) can be produced
loading