7b When connected to the motorized valve, wire the motorized
valve and the thermostat as shown below (for heating-only
applications).
Power supply
X1M
C
com
H
The output relays (H and C) are voltage-free contacts. Refer
to "Technical characteristics" on page 11 for maximum load.
8
Fasten the thermostat with the supplied screws.
Be careful not to pinch the wiring when fastening.
9
Put the transparent cable protection back into place and fix
the cable protection with the screw.
10 Close the thermostat cover.
11 Remove the protective film from the LCD.