S&P ECOAIR LC Manual Del Usuario página 16

Ocultar thumbs Ver también para ECOAIR LC:
"Interval" functions:
This function is useful when the extract
fan is installed in very wet (near the sea)
or the ambiance exceeds the set level
for a very long time. To prevent the fan
to run for hours without stopping, the
"Interval" function allows the fan to
switch off automatically one hour after it
began to run. The extractor keeps
switched off during the set time for
interval function. If the humidity level is
still above the set level when the time
interval is over, the extract fan switches
on again and run during one hour.
When, on he contrary, the extract fan
never switches on because the humidity
level is always very low or it is
improperly
installed
appliance, behind a door, in an area with
no air movement) putting the 1 dip-
switch interval function to position "ON",
the fan switches on automatically during
1 hour and then it keeps switched off
during the set time for interval function.
This function causes the fan to run
whatever the humidity level.
To select this function put the
ON
dip-switch 1 to posi ion "ON"
1
To adjust the pre-set time for interval
function, use the dip-switches 2 and 3.
Automatic operation with external switch
to override the extractor:
The extractor is connected to the main
supply with three wires (fig.4a y 4b).
Operation
as
previous
operation", with he facility to override
the humidistat by means of the light
switch when the humidity level in the
room is lower than the selected level. In
16
(above
heating
"Automatic
this case the extractor continues to
operate for the selected period of time
(over-run timer) after the switch light has
been switched off.
ATENTION: When the humidity rate is
above
the
selected
automatic option takes precedence
over the manual and the unit cannot
then be switched off using a switch.
Start-up timer func ion:
In this operation, the "start-up timer
function"
allows to delay the extractor
start-up for a period of 50 seconds. So
that, for example, the fan does not
switch on if
he usage time of the
bathroom is less than 50s.
If you exceed the 50s, the fan switches
on, and when the light switches off, runs
the time set by the timer.
This func ion is selected with the dip-
switch 8.
EcoAIR MLC
EcoAIR LC version similar to H model,
fitted wi h an internal pull cord switch to
operate the boost when the humidity
level is below the set point (fig.5)
When switching off the internal pull cord
switch, the fan continues to operate at
boost the time set by the timer then runs
at trickle speed, unless the humidity level
exceeds the set point.
EcoAIR DLC
Models provided with a PIR (passive
infra-red) detector (movement detected
with a maximum distance of 4 metres)
and with an adjustable "run on" timer (1
to 30 minutes).
The selection of the run on time is done
with the dip-switches 6 and 7: setting
between 1, 5, 15 and 30 minutes
value,
the
loading

Este manual también es adecuado para:

Kit ecoair lc + ct-17/18Ecoair lc + ct-17/18Ecoair tlcEcoair hlcEcoair mlcEcoair dlc ... Mostrar todo