Operation; During Operation; Power Down - THERMOBILE IMA US Manual Del Usuario

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

7.
Check the connection of the room
thermostat.
Do not remove the cap when you do not use
a room thermostat.
Remove the cap to connect a room
thermostat.
8.
Install the flue (3.2 ft and a raincover).
9.
Make sure the heater is switched off. See fig.
7.
10. Check the power supply: see the
identification plate.
11. Fit a plug at the end of the cable.
Caution
Only an authorised person is allowed to
put a plug at the cable.
Check the direction of rotation of the fan, see
"Fan rotation check".
12. Put the plug in the socket.
13. Press the reset switch of the burner (A), see
fig. 6.
3.3
Fan rotation check
1.
Set the rotary switch (A) to position 1, see fig.
7. The fan starts rotating.
2.
Feel if the fan blows air outside.
Caution
If the fan does not blow air outside, the
stream of air does not cool the heater.
The maximum thermostat will shut off
the heater.
3.
If the fan rotates in the wrong direction: stop
the heater.
4.
Disconnect the electric power and contact the
dealer.
3.4
Power up
Power up for heating:
1.
Open the fuel valve (B), see fig. 8.
2.
Set the rotary switch (A) to position "2" , see
fig. 7.
The fan starts automatically after the heated
air has reached a temperature of 95 °F. To
start the fan direct, set the rotary switch to
position "3".
Caution
Do not switch on the heater when there
is no fuel, or when the connected fuel
tank is empty.
3.
Set the room thermostat.
The heater supplies warm air after
approximately 20 seconds.
IMA-US
Power up for blowing:
1.
Set the rotary switch (A) to position "1", see
fig. 7. The fan starts blowing.
4
4.1
4.2
Power down for heating:
1.
Set the rotary switch (A) to position "0" , see
fig. 7.
The magnetic valve closes and stops the fuel
supply.
2.
Disconnect the electric power.
Power down for blowing:
1.
Set the rotary switch (A) to position "0" , see
fig. 7.
2.
Disconnect the electric power.
40.020.940 - rev. 04 - 2011

OPERATION

During operation

Hot
Do not touch the flue with rain cover, nor
the air outlet! The flue with rain cover
and the air outlet become hot during
operation!

Power down

Caution
After you switch off the heater, the fan
still rotates. The fan cools the heater to
avoid damage caused by overheating.
The fan stops automatically.
Do not remove the plug from the socket
until the heater fully stops!
English