Calibrating The Sensor; Priming The Peristaltic Pump; Settings; Settings Menu - Zodiac pH expert Manual De Instalación Y De Uso

Ocultar thumbs Ver también para pH expert:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 42
3.3 Calibrati ng the sensor
For the appliance to operate accurately and reliably, the pH sensor must be calibrated regularly (on installati on,
on re commissioning aft er wintering, and every 2 months when in use).
• Rinse the ti p of the pH sensor with clean water using the supplied bott le of H²O fi lled with tap water.
• Shake it to remove excess water.
Don't wipe the sensor or touch its ti p!
• Immerse the sensor in the bott le containing the pH7 buff ering soluti on.
• Press
for 5 seconds unti l
• Press
, the progress bar is displayed:
• Aft er about 30 seconds, the pH sensor reliability is displayed as a percentage. If the value is above 25%, conti nue the
calibrati on process, otherwise power off the appliance using the 0-1 butt on, replace the buff ering soluti on and/or the
pH sensor, then restart calibrati on.
• Rinse the ti p of the pH sensor with clean water using the supplied bott le of H²O fi lled with tap water.
• Shake it to remove excess water.
• Immerse the sensor in the bott le containing the pH 4 buff ering soluti on.
• Press
to display
• Press
to display the progress bar:
• Aft er about 30 seconds, the pH sensor reliability is displayed as a percentage. If the value is above 25%, press
to complete the calibrati on process, otherwise power off the appliance using the 0-1 butt on, replace the buff ering
soluti on and/or the pH sensor, then restart calibrati on.
• Rinse the ti p of the pH sensor with clean water using the supplied bott le of H²O fi lled with tap water.
• Shake it to remove excess water.
• Fit the sensor back onto its holder.
3.4 Priming the peristalti c pump
The peristalti c pump is self-priming. However, it can be run manually by pressing
to inject corrector product as long as the key is kept pressed down.
3.5 Setti ngs
3.5.1 «Setti ngs» menu
Language
pH set point
Dosage
Alkalinity level
«OFA» Over Feed Alarm
Calibrati on
Filtering operati on detecti on
Press simultaneously on
To exit the menu, press
Select "Yes" or "No" using the following keys
Confi rm by pressing
H0434900.A - EN - 2013-11
Menu
and
for 5 seconds when the appliance is powered on:
:
.
is displayed, then
,
,
,
French
7.4
Acid
Standard (100 < TAC < 150 ppm)
4 hours
Acti vated 2 points (pH7 and pH4)
Acti vated «On»
and
,
. The peristalti c pump will then run
Default Setti ngs
,
EN
6
Tabla de contenido
loading

Tabla de contenido