4.2 Wintering

• During wintering it is recommended to rinse the peristalti c tube using clean water by carrying out
manual priming (see §3.4).
• Then place the roller holder at 6 o'clock to facilitate restarti ng.
• Remove the pH sensor from its holder and store it in its original bott le, or in a container fi lled with tap
water.
• Close off the sensor holder if necessary.
Always keep the sensor in water and protected from freezing.
5. Troubleshooti ng

5.1 Display of the regulator

Message
«Level»
• Protector
empty
• Floater blocked
• Level sensor short circuited.
«OFA Alarm»
First step in the over feed safety
system acti vated (ti me > 75%)
«OFA Stop»
Second step in the over feed safety
system acti vated (ti me = 100%)
«OFA Check»
pH sensor measurement test when
the «OFA Stop» was acti vated
during a previous fi ltering cycle.
«Flow»
• Filtering stopped
• Incorrect connecti on
«Error»
• Used Buff er soluti on(s)
• pH sensor dirty
• Defecti ve pH sensor
«Error
Setti ng error
Parameter»
5.2 Appliance malfuncti ons
Malfuncti on
The appliance
always displays a pH
value close to 7.0
The appliance
always displays an
unsuitable value
or the measure is
constantly unstable
9
Possible causes
product
container
Possible causes
Cable problem and/or BNC
connector problem
• pH sensor connecti on cable is
damaged
• There is an air bubble in the
pH sensor bulb
• The pH sensor is worn
• The pH sensor cable is too
close to an electric cable
causing disturbances
• The sensor is not correctly
fi tt ed on the piping.
• Replace the corrector product container
• Check that the white fl oater on the sucti on cane is in working
order
• Change the sucti on cane
• Press
to stop the alarm
• Check the sensor and/or the pool pH level
• Press
to stop the alarm
• Check the sensor and/or the pool pH level
• Wait for the end of the procedure (1 hour) then check the
sensor and/or the pool pH level.
• Start and/or check the fi ltering
• Check the electric connecti ons
• Replace the buff er soluti on(s)
• Clean the pH sensor using a 10% HCl soluti on
• Replace the pH sensor
• Press
to cancel the fault
• Replace the electronic card
• Check that the connecti on between the sensor and the
control box is not short circuited (between the cable's
central core and the external shielding)
• Check that there is no humidity and/or condensati on at the
BNC connector level
• Check the cable and/or the BNC connector
• Positi on the pH sensor verti cally and shake gently so that
the air bubble rises to the top (sensor must be mounted
verti cally or at a 45° angle maximum, seer §2.4)
• Replace the pH sensor
• Reduce the distance between the appliance and the sensor
• Place the sensor in a more suitable locati on (see §2.2.1)
Soluti ons
Soluti ons
H0434900.A - EN - 2013-11