Zirkon BioStar S - Additional Information for the Instructions
Instructions for the use of Zirkon BioStar S in your Sirona inLab
General information:
Basically, you can use your Zirkon BioStar S blocks as other blocks for your Sirona
Programming of the Sirona inLab
1. Place the Zirkon BioStar S block as usual.
2. Chose from the seleccion of blocks "VITA In-Ceram
3. Enter the "Z-Code" indicated on the package completely, including "*", as for instance: *Z24912A.
4. Iniciate milling
®
VITA In-Ceram
YZ, Sirona inLab
Depending on the material, the recommended sintering temperatures are:
Sintering program for Zirkon BioStar white opaque / HT (high transluzent) / Colour / S
Preheating rate up to 900 °C
°C / min.
Holding time at 900 °C
Preheating rate to final
temperature of 1.450 °C
Holding time at final
temperature of 1.450 °C
Cooling rate down to 900 °C
°C / min.
Holding time
at 900 °C
Cooling rate down
to 200 °C
Total time in h
Preheating rate up to 900 °C
°C / Min.
Holding time at 900 °C
Preheating rate to final
temperature of 1.500 °C
Holding time at final
temperature of 1.500 °C
Cooling rate down to 900 °C
°C / min.
Holding time
at 900 °C
Cooling rate down
to 200 °C
Total time in h
8
®
®
or inLab
®
®
and inLab
MCXL Systems are registered trademark of the manufacturers.
single crown
°C
min.
15
900
15
1450
10
900
10
4 h 20 min.
Sintering program for Zirkon BioStar Z white translucent
single crown
°C
min.
15
900
15
1500
10
900
10
4 h 29 min.
MCXL System:
®
YZ" the corresponding block size for the process.
bridge of 3 - 4 pieces
°C
59
12
5
900
36
12
30
1450
55
5
5
900
70
5
8 h 29 min.
bridge of 3 - 4 pieces
°C
59
12
5
900
40
12
30
1500
60
5
5
900
70
5
8 h 43 min.
®
or inLab
®
MCXL system
®
system.
brigde of > 4 pieces &
circular bridges
min.
°C
73
8
15
900
46
8
120
1450
110
4
10
900
135
4
11 h 02 min.
brigde of > 4 pieces &
circular bridges
min.
°C
73
8
15
900
50
8
120
1500
120
4
10
900
135
4
11 h 20 min.
min.
110
30
69
120
138
20
175
min.
110
30
75
120
150
20
175