negative pole terminal).
> A Spark can arise if the charger is connected to the battery whilst
connected to the mains. Please ensure it is disconnected from
the mains before connecting or disconnecting the red and black
charging leads to or from the battery.
OVERVIEW FUNCTIONS
> Lead acid charger for 2V/6V/12V batteries.
> Protection against short-circuit, wrong polarity and overcharge
protection.
> Charging with IU-curve
> Suitable for float charging
> Trickle charge with current adjustment
COMMISSIONING
Insert the relevant mains input plug so that it connects to the two
power contacts and push the plug until it clicks into place.
Ensure that you hear the input plug click into the charger to ensure
the unit is safe to use.
To release the input plug, push the release button (with a pen for
example) and move the plug backwards.
1. Adjust secondary voltage
Adjust the right voltage on the charger with the provided adjusting
tool.
2. Connect charger to the battery with the correct polarity
First connect the charger to the battery to be charged. Connect the
red pole terminal to the positive pole (+) of the battery, then the
black pole terminal to the negative (-) pole of the battery. Make
sure that the battery terminals are connected correctly. If the bat-
tery is installed in the vehicle and the battery terminals are not
accessible, please consult the vehicle manual for advice.
If the clamps are accidently attached to the poles the wrong way
around, the "FAULT" LED lights red. Reconnect the terminals with
the correct polarity immediately.
3. Connect the device to the mains supply
Insert the mains plug of the charger into the socket and switch on.
The „POWER" LED will lights green.
4. Battery is charged