Kübler CODIX 54U Instrucciones De Puesta En Servicio página 17

Contador indicador electrónico
Ocultar thumbs Ver también para CODIX 54U:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

4.1 Polarity of the inputs
4.2 Switching on the 30 Hz filter (INP A)
4.3 Multiplying factor
4.4 Dividing factor
4.5 Decimal point
npn: switching for 0 V
pnp: switching for +U B
30 Hz filter off (f max )
30 Hzfilter on
It can be set from 00.0001
up to 99.9999.
The decimal point is set to
4 decimal places.
„0" is not accepted!
It can be set from 00.0001
up to 99.9999.
The decimal point is set to
4 decimal places.
„0" is not accepted!
The decimal point defines
the way of displaying the
count values. It does not
affect counting.
0
no decimal place
0.0 one decimal place
0.00 two decimal places
0.000 three decimal places
4.6 RESET mode (totaliser 1)
4.7 RESET Mode (totaliser 2)
manual reset via the red
RESET key and
electrical reset via the
RESET input
no reset (red RESET key
and RESET input locked)
only electrical reset via the
RESET input
only manual reset via the
red RESET key
manual reset via the red
RESET key and
electrical reset via the
RESET input
no reset (red RESET key
and RESET input locked)
only electrical reset via the
RESET input
only manual reset via the
red RESET key
17