OFA_Time_____off
o
§
§
Calibration___7/4pH
o
§
§
Man_Temperature_25°C_
o
§
§
Save and escape Program setup with ESC key
•
Exit______save
o
§
Priming
o
Priming Pump Keep Press
•
1) Input pH or Redox Probe
2) Input Temperature Probe (PT100)
3) Input Level Probe (Product Tank
4) Input Flow Rate (High Voltage 230 Vac)
5) Output Relay Alarm remote (Dry contact, Relay 250
Vac 10 A)
6) Output Relay Drive Solenoid Valve (Dry contact,
Relay 250 Vac 10 A)
7) Power Supply 230 Vac
8) Switch Power Supply
Code 0000137728
Adjust value
and
It's possible to adjust OFA time in minutes
Adjust value
and
It's possible to select 2 points 7 and 4 pH, 1 point only 7pH or function disable; for
Redox function disable only.
Adjust value
and
pH measure only.
Adjust value with
for 3 seconds
Wire Connection:
up or down key and confirm with
rev. 1.0
8
3