Positioning The Logs; Connecting To The Gas Supply; Operating Instructions; Lighting - Dru DIABLO Manual De Instalación Y Guía Del Usuario

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 33
INSTRUCTIONS FOR INSTALLATION

Positioning the logs

Position the logs as follows:
• Lay the large log against the back wall.
• Fill the burner with the vermiculite mixture (the mixture
is packed in a plastic bag with the log set).
• Spread evenly over the burner tray and the surrounding
tray.
• Position the other logs as illustrated in fig. 5.The front of
the centre log should rest on the burner.
• Put the two small blocks at the back on the left and on
the right under the slanting blocks.These serve to hide
the burner from view.
Do not lay the logs in any other way, as this could cause
the formation of soot. Do not use any materials other
than those supplied.The materials supplied are non-flam-
mable and have been made specially for this appliance.

Connecting to the gas supply

Connect the gas supply to the gas control valve with 3/8"
inner thread.
In the connecting pipe an approved connecting gas tap
with a coupling should be included.This should be placed
outside the casing.
Furthermore please note that:
• Expel all air from the supply pipe before coupling the
appliance.
• Do not turn the control tap when connecting the gas
supply.
• Avoid any tension on the control tap or pipes.
• Check that the connection is gastight.
fig. 5
fig. 4

OPERATING INSTRUCTIONS

OPERATING INSTRUCTIONS
The control buttons are located behind the flap at the bot-
tom of the heater front.

Lighting

Press button A and turn to the left to the small flame
The flame will ignite at
behind the glass is alight. If that is the case, hold button A
firmly pressed for another 5 seconds.Then release button
A and check that the pilot light is still burning. Now turn
button A to the large flame
valve of the control block. Depending on the setting of the
control button B, high or low flames will be visible.
Remote control
The level of the flames can be regulated with the remote
control, which will turn button B; to the right for a smaller
flame, to the left for a larger flame. Controlling button B
by hand will give the same result.This will require a certain
effort and it is quite normal to hear clicking.

Pilot light setting

If the heater is not in use but you would like the pilot light
to remain alight, set button A to the small flame.The gas
supply to the main burner will then be switched off.

Switching off

Turn button A to the "0" setting.The gas supply to the
burners will then be switched off.

Important

A built-in safety lock is activated when the appliance is
switched to "OFF" (closed down setting).Therefore, wait
5 minutes before relighting the heater.Within this period,
do not try to push the lighting button, as this has been
blocked by the safety lock. Do not force the button, as this
may result in damage to the mechanism.
10
fig. 6
. Check that the pilot light
, which will open the main
.
loading