Configuration Menu - Lamborghini Caloreclima SILVER 24C Instrucciones De Uso, Instalación Y Mantenimiento

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

SILVER 24C - 34C
A
C
B
D
TEST mode activation
Press the heating buttons (details 3 and 4 - fig. 1) together for 5 seconds to activate the
TEST mode. The boiler lights at the maximum heating power set as described in the fol-
lowing section.
The heating and DHW symbols (fig. 23) flash on the display; the heating power will ap-
pear alongside.
fig. 23 - TEST mode (heating power = 100%)
Press the heating buttons (details 3 and 4 - fig. 1) to increase or decrease the power
(Min.=0%, Max.=100%).
By pressing the DHW "-" button (detail 1 - fig. 1), boiler output is immediately adjusted
to min. (0%). By pressing the DHW "+" button (detail 2 - fig. 1), boiler output is immedi-
ately adjusted to max. (100%).
If the TEST mode is activated and enough hot water is drawn to activate the DHW mode,
the boiler remains in TEST mode but the 3-way valve goes to DHW.
To deactivate the TEST mode, press the heating buttons (details 3 and 4 - fig. 1) together
for 5 seconds.
The TEST mode is automatically deactivated in any case after 15 minutes or on stopping
of hot water drawing (if enough hot water has been drawn to activate the DHW mode).
Heating power adjustment
To adjust the heating power, switch the boiler to TEST mode (see sec. 4.1). Press the
heating buttons (details 3 and 4 - fig. 1) to increase or decrease the power (min. = 00 -
max. = 100). Press the RESET button within 5 seconds and the max. power will remain
that just set. Exit TEST mode (see sec. 4.1).
fig. 22
eco
2
comfort
1
3
0
4
reset
cod. 3541I680 - Rev. 01 - 09/2016

Configuration Menu

The configuration Menu is accessed by pressing the DHW buttons together for 10 sec-
onds. 23 parameters are available, indicated by the letter "b", which are not modifiable
from Remote Timer Control.
Press the Heating buttons to scroll the list of parameters in increasing or decreasing or-
der. Press the DHW buttons to view or modify the value of a parameter: the modification
will be automatically saved.
Contents Description
Range
0=Natural Gas
b01
Gas type selection
1=LPG
1=Bithermal
instantaneous
2=Heating only
(3-way valve)
b02
Boiler type selection
3=Monothermal
instantaneous
4= Storage (with
3-way valve)
0=Pressure
switch
System water pressure protec-
b03
tion selection
1=Pressure trans-
ducer
Fan max. frequency in DHW
0-220Hz
(b02=1)
Fan max. frequency in DHW
0-220Hz
(b02=2)
b04
Fan max. frequency in DHW
0-220Hz
(b02=3)
Fan max. frequency in DHW
0-220Hz
(b02=4)
Fan max. frequency in heating
0-220Hz
(b02=1)
Fan max. frequency in heating
0-220Hz
(b02=2)
b05
Fan max. frequency in heating
0-220Hz
(b02=3)
Fan max. frequency in heating
0-220Hz
(b02=4)
Fan min. frequency in DHW/
0-165Hz
heating
(b02=1)
Fan min. frequency in DHW/
0-165Hz
heating
(b02=2)
b06
Fan min. frequency in DHW/
0-165Hz
heating
(b02=3)
Fan min. frequency in DHW/
0-165Hz
heating
(b02=4)
Boost level/Max. Power limit in
DHW
0-100%
(b02=1)
Not implemented (b02=2)
b07
Boost level/Max. Power limit in
DHW
0-100%
(b02=3)
Not implemented (b02=4)
Boost Timer/Max. Power limit
in DHW
0-255%
(b02=1)
Not implemented (b02=2)
b08
Boost Timer/Max. Power limit
in DHW
0-255%
(b02=3)
Not implemented (b02=4)
b09
Fan min. frequency Offset
0-220Hz
(b02=1)
Fan min. frequency Offset
0-220Hz
(b02=2)
Fan min. frequency Offset
0-220Hz
(b02=3)
Fan min. frequency Offset
0-220Hz
(b02=4)
Default
SILVER 24C
SILVER 34C
0=Natural Gas
0=Natural Gas 0=Natural Gas
3=Monother-
3=Monothermal
1=Bithermal
mal instanta-
instantaneous
instantaneous
neous
0=Pressure
0=Pressure
0=Pressure switch
switch
switch
180Hz
180Hz
180Hz
170
200
180Hz
165Hz
165Hz
165Hz
150
180
165Hz
55Hz
55Hz
55Hz
45
45
55Hz
100%
--
--
100%
100%
100%
--
--
60seconds
--
--
60seconds
60seconds
60seconds
--
--
10Hz
10Hz
10Hz
10Hz
10Hz
10Hz
EN
23
Tabla de contenido

Solución de problemas

loading

Este manual también es adecuado para:

Silver 34c

Tabla de contenido