lamp comes on); when pressing the button a second time (while the pilot lamp is on), the TIMER is activated
and thus the motor stops after 5' (the pilot lamp flashes). Button D: drives the motor in third speed (the
corresponding pilot lamp comes on); when pressing the button a second time (while the pilot lamp is on) , the
TIMER is activated and thus the motor stops after 5' (the pilot lamp flashes). Button E: drives the motor in fourth
speed (the corresponding pilot lamp comes on); when pressing the button a second time (while the pilot lamp
is on) , the TIMER is activated and thus the motor stops after 5' (the pilot lamp flashes).
Pay special attention to the grease filters: if the model purchased has the commands shown in Figure
17: the grease filters must be cleaned approximately once every 30 hours of operation. To remove the filters:
press inward on the clamps at the handles and pull the filter downward. Wash out the filter using a neutral
soap.
If the model purchased has the commands shown in Figure 18: the grease filters must be cleaned approximately
once every 30 hours of operation (when the light button lamp comes on) (Fig.18S). To remove the filters: press
inward on the clamps at the handles and pull the filter downward. Wash out the filter using a neutral soap.
Once the cleaned filters are reinstalled, to reset the counter hold the light button pressed down for about 1"
(Fig.18A) while the corresponding pilot lamp (S) is on. For further information, see the Commands in Fig.18
in the paragraph entitled "Operation".
Replacing the charcoal filters: If the unit is a filtering hood, the charcoal filters must be replaced: to remove
them press inward on the clamp (Fig.19) and rotate the filter downward until the 2 tabs can be removed from
the housing.
If the model purchased has the commands shown in Figure 17, the charcoal filters must be replaced every
120 hours of operation). If the model purchased has the commands shown in Figure 18, the charcoal filters
must be replaced each time the light button (Fig.18S) lamp flashes (i.e. every 120 hours of operation).
Lighting: to remove the halogen lamps, turn the locknut counter-clockwise (Fig.20). Replace with the same