Troubleshooting - Steamfast SF-145 F Guía De Usuario

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

PROBLEM
Unit fails to heat up. Red Power
Indicator Light DOES NOT
illuminate.
Unit fails to heat up. Red Power
Indicator Light DOES illuminate;
green Heating Indicator Light DOES
NOT illuminate.
Unit heats up, but fails to steam. Both
red Power Indicator Light and
green Heating Indicator Light DO
illuminate.
NOTE: Always allow sufficient
time for unit to heat up and begin
producing steam.
Steam output is weak or intermittent.
Excessive moisture left on floor
during mopping.
NOTE: It is normal for some
amount of moisture to be left
behind. Allow floor some time to
air-dry once mopping is complete.
Floor surfaces appear cloudy or
streaky after steaming.
Floor Lights do not illuminate when
Floor Light Switch is pressed.
No solution is sprayed when Solution
Spray Button is pressed.
12

Troubleshooting

POSSIBLE CAUSE
Unit is not plugged in.
Unit's main power is not on.
Household circuit breaker / ground
fault interrupter has tripped or blown
a fuse.
Unit is damaged or otherwise in
need of repair.
No water in Boiler.
Mineral build-up in unit.
Unit is damaged or otherwise in
need of repair.
Water level in Boiler is running low.
Mineral build-up in unit.
Microfiber Pad has become
saturated with moisture.
Boiler has been overfilled.
Microfiber Pad is dirty.
Hard water residue on floor.
Unit's main power is not on.
Lights are burnt out or
malfunctioning.
Solution Tank is empty.
Spray mechanism is clogged or
malfunctioning.
SOLUTION
Plug power cord into electrical outlet.
Press On/Off Switch until it clicks.
Reset circuit breaker / ground fault
interrupter, or replace fuse. For
assistance, contact a licensed electrician.
Immediately cease usage and unplug.
Contact Consumer Service for
assistance (see Page 13 for details).
Refer to Adding Water procedure
on Page 8 to fill Boiler.
Refer to Mineral Build-up section on
Page 11 for cleaning procedure.
Immediately cease usage and unplug.
Contact Consumer Service for
assistance (see Page 13 for details).
Refer to Adding Water procedure
on Page 8 to refill Boiler.
Refer to Mineral Build-up section on
Page 11 for cleaning procedure.
Remove Pad and replace with a
fresh dry one. To purchase
additional Pads, contact Consumer
Service (see Page 14 for details).
Filling Boiler with more than 10 oz.
(300 ml.) of water interferes with
steam production, resulting in water
condensation in steam.
Drain some water out of Boiler.
Always use included Measuring Cup
to fill Boiler with correct amount of
water (see Page 8 for details).
Replace Microfiber Pad with a clean one.
Switch to distilled water.
Press On/Off Switch until it clicks.
Contact Consumer Service for
assistance (see Page 13 for details).
Refer to Adding Cleanfast Hard
Floor Solution procedure on Page
8 to refill Solution Tank.
Contact Consumer Service for
assistance (see Page 13 for details).