EHMB
To guarantee the switching function of the proximity sensor:
Set proximity sensor (E) so that there is a gap of X = 0.5 mm to
the cams.
Mount each proximity sensor using the supplied lock nut (tight
ening torque of the lock nuts è Operating instructions of the
proximity sensor).
To install additional trip cams (è Catalogue specifications,
è www.festo.com/catalogue).
Installing additional trip cams:
– Insert cam (C) into the cut-out on the groove of the fixture.
For the EHMB-32, this requires removal of the sensor brack
et (tightening torque when reattaching: 1.2 Nm).
– Swivel cam (C) either upwards or downwards.
– Insert additional cams into the cut-out as needed.
24
Fig. 8
Fig. 9
Festo – EHMB – 1606b English
(E)
(C)
(D)