Operating Instructions
Electronic Po si ti on Indicator
and Electronic Frequency Meter
E5024E0432
1.1 Safety instructions and warnings
Only use this display
– according to its intended purpose
– if its technical condition is perfect
!
– adhering to the operating
instructions and the general
safety instructions.
1.2 General safety instructions
1. Before carrying out any installation or mainte-
nance work, make sure that the power supply
of the digital display is switched off.
2. Only use this digital display in a way according
to its intended purpose:
If its technical condition is perfect.
Adhering to the operating in structions and the
general safety instructions.
3. Adhere to country or user specific regulations.
4. The digital display is not intended for use in
areas with risks of explosion and in the
branches excluded by the standard EN 61010
Part 1.
5. The digital display should only operate if it has
been correctly mounted in a panel, in accor-
dance with the chapter "Technical data".
1.3 Use according to the intended
purpose
The digital display may only be used as a panel-
mounted device. Applications of this product may
be found in industrial processes and controls, in
manufacturing lines for the metal, wood, plastics,
paper, glass, textile and other processing
industries.
Over-voltages at the terminals of the digital dis-
play must be kept within the limits in Category II.
If the digital display is used to monitor machines
or processes in which, in case of a failure of the
device or an error made by the operator, there
might be risks of damaging the machine or caus-
ing accidents to the operators, it is your respon-
sibility to take appropriate safety measures.
MN05401004E
1.4 Description
• 6-digit position indicator and frequency meter
• Red LED display, character height 8 mm
[0.31 in.]
• Display range -199 999 – 999 999
• Lead zero blanking
• Programming via two setting keys on the front
side
• During programming, the display guides the
user with text prompts
• Position indicator operating modes
– Count input INP A + count direction input
INP B (Cnt.Dir)
– Differential count INP A - INP B (up.dn)
– Totalizing INP A + INP B (up.up)
– Count Up/Down INP A 90° INP B x 1
(quad)
– Count Up/Down INP A 90° INP B x 2
(quad2)
– Count Up/Down INP A 90° INP B x 4
(quad4)
• Frequency meter
– Frequency input INP C
– Value conversion and display in 1/s or
1/min
2. Inputs
INP A
Dynamic count input.
INP B
Dynamic count input.
INP C
Dynamic frequency input.
1