How To Wire Your Ceiling Fan - Emerson BUILDER Serie Manual Del Usuario

Ocultar thumbs Ver también para BUILDER Serie:
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

BP7312-4 CF700.qxp_ BP7312 2/27/15 5:14 PM Page 13
If you feel that you do not have enough electrical
wiring knowledge or experience, have your fan
installed by a licensed electrician.
To avoid possible electrical shock, be sure electricity
is turned off at the main fuse box before wiring.
NOTE: If you are not sure if the outlet box is grounded,
contact a licensed electrician for advice, as it must be
grounded for safe operation.
5.1
Connect the green grounding lead from the hanger ball
and the green grounding lead from the hanger bracket
to the grounding conductor of supply (this may be a
bare wire or wire with green colored insulation).
Securely connect wires with wire connectors (supplied)
(Figure 16).
This product is designed to use only those parts
supplied with this product and/or any accessories
designated specifically for use with this product by
Emerson Electric Co. Substitution of parts or
accessories not designated for use with this product
by Emerson Electric Co. could result in personal injury
or property damage.
5.2
Securely connect the fan motor white wire to the supply
white (neutral) wire using wire connector (supplied)
(Figure 17).

5. How to Wire Your Ceiling Fan

WARNING
!
WARNING
!
GROUND
CONDUCTOR SUPPLY
LISTED WIRE
CONNECTOR
GREEN WIRE
(GROUND) FROM
HANGER BALL
GREEN WIRE
(GROUND) FROM
HANGER BRACKET
Figure 16
Figure 17
Please contact 1-800-654-3545 for further assistance
13
SUPPLY WHITE
(NEUTRAL)
LISTED WIRE
CONNECTOR
FAN MOTOR
WHITE WIRE
emersonfans.com
U.L. Model No.: 52-ANT