Spray off loosened dirt with the
high-pressure ray.
Set dosing value for detergent to "0"
after operation with cleaners. Start
the appliance and rinse for one min-
ute with clear water with an open
hand spray gun.

Interrupting operation

Release the lever of the hand-spray
gun; the device will switch off.
Release again the lever of the
hand-spray gun; the device will
switch on again.
Operational readiness period
On opening the hand-spray gun, the
device starts within the readiness peri-
od. The indicator lamp glows green.
The readiness period is over if the
hand-spray gun remains closed for 30
minutes. The indicator lamp blinks
green.
Reset readiness period
Set the appliance switch to "0".
Wait for a while.
Set the appliance switch to "I".
Customer Service can switch the de-
vice to continuous operations.
Turn off the appliance
Set the appliance switch to "0".
Disconnect the mains plug from the
socket.
Shut off water supply.
Activate hand spray gun until de-
vice is pressure-less.
Press the safety lever of the hand-
spray gun to secure the lever of the
pistol against being released acci-
dentally.
Danger
Danger of scalding by means of hot wa-
ter. The water remaining in the switched
off device can get heated up. When you
remove the hose from the water inlet, the
heated water can spray out and cause
scalding. Remove the hose only when
the device has cooled down.

Storing the Appliance

Insert the hand-spray gun in the
holder.
Wind up the high-pressure hose
and hang it over the hose storage.
Wind the connection cable around
the cable holder.
Fasten the plug with the mounted
clip.

Frost protection

Warning
Frost will destroy the not completely
water drained device.
Store the appliance in a frost free area.
If you cannot store it in a frost-free
place:
Drain water.
Emptying the detergent tank (see
"Care and Maintenance/ as re-
quired").
Pump in conventional frost protec-
tion agents through the appliance.
Note
Use normal glycol-based anti-freezing
agents for automobiles.
Observe handling instructions of the
anti-freeze agent manufacturer.
Operate device for max. 1 minute
until the pump and conduits are
empty.