Fein Slugger JCM 200 QX Instrucciones De Uso página 18

Ocultar thumbs Ver también para Slugger JCM 200 QX:
Idiomas disponibles

Idiomas disponibles

OBJ_BUCH-0000000130-003.book Page 18 Thursday, December 15, 2016 1:40 PM
en
18
Adjusting the stroke range (figure 11).
Hold the power tool firmly
CAUTION
with one hand when releasing
the two fastening levers.
To move the fastening levers over each other,
pull a fastening lever outward and then turn
the fastening lever in 45° steps.
Loosen both fastening levers with the other
hand.
Adjust the desired stroke range.
Tighten both fastening levers again.
Adjusting the working position
(JCM 256 U) (figure 12).
Release the fine-adjustment clamping lever.
Adjust the desired position. The drill stand
can be moved toward the front or rear on the
magnetic foot, and can be turned toward the
right and left.
Tighten the clamping lever again.
Fig.12
loading