OBJ_BUCH-0000000130-003.book Page 7 Thursday, December 15, 2016 1:40 PM
Extension cable.
If the use of an extension cord
WARNING
is required, its length and con-
ductor cross-section must be adequate for the
application in order to prevent a voltage drop
in the extension cord, power loss and over-
heating of the power tool. Otherwise, the
extension cable and power tool are prone to
electrical danger, and the working efficiency is
decreased.
Intended use of the power tool:
Magnetic core drill unit for drilling with core
drill bits and solid drill bits, reaming, counter-
sinking and tapping on materials with surfaces
suitable for magnets in weather-protected
environments using the application tools and
accessories recommended by Slugger.
Operation of the power tool off power generators.
This power tool is also suitable for use
with AC generators with sufficient power
output that correspond to the Standard
ISO 8528, design type G2. This Standard is
particularly not complied with when the so-
called distortion factor exceeds 10 %. When
in doubt, please refer to the generator
instruction/specification guide.
Recommended dimensions of extension cords
at an operating voltage of 120 V – single-
phase a. c., with only JCM 200 QX, JCM 200 U,
JCM 200 auto, JCM 256 U connected:
Max. cable length, ft
Max. cable length, m
≤ 100
100
200
–200
–300
Min. conductor size
Min. conductorcross-
A.W.G.
section, mm
16
14
12
Operating the power tool off
WARNING
power generators whose no-
load speed exceeds the voltage value on the
type plate of the power tool is prohibited.
en
7
≤ 30
30
60
–60
–100
2
1.5
2.5
4