MANUAL.- Programmer control is accessed so that the six positions may be manually
MANUAL
selected: closed, filtration, wash, back-wash, re-circulation and empty.
PUMP ON/OFF.- used to start or stop the pump in manual position.
PUMP
ON/OFF
TURN.- causes the valve to rotate and move to the following position, the screen will
display the current valve position.
VALVE
TRANSMISSION
= - transmission of commands to the valve.
AUTOMATIC
AUTO
SCREW MENU
Menu forward: the screen allows the language to be selected; this will
affect all screen messages.
Menu forward displays the screen which permits the equipment day and
time to be modified. This operation is only required once because the equip-
ment is fitted with a battery-operated internal clock which will maintain the
time.
When the battery requires replacing, the valve module will flash eight times
and the installer should be contacted for replacement. (See Appendix 5)
The customer's full filtration process must be reprogrammed.
The factory program is maintained.
When Menu forward is pressed, the screen will display the information for
the first program (the equipment has two programs). This screen will indi-
cate the number for the program being displayed and the second line shows
the programmed ON and OFF times.
Language selected:
ENGLISH
Day: 20.10.2002
Time: 15.30
FILTRATION PROGRAMM 1
on: 6:45
off: 9:50
10