Description of functions and controls

The controls of the machine are described here below
with reference to the following figure.
L1
E1
C2
I1
When the 'I1' ON/OFF switch is pressed the generator
turns on. After the internal diagnostic phase of about 7
seconds, the generator starts.
Press the 'E1' knob and
adjust
pressure
by
turning
the
regulating
filter knob 'R1' and set it
to 3.5÷5 bar. To do this,
the filter knob should be
pulled until released and
turned either clockwise
or
anticlockwise
to
respectively decrease or
increase pressure; after
setting pressure, the filter
knob should be pushed
until released. Make sure that the air delivery is at
least 115 l/min.
The generator is now ready to use, and by turning the
'E1' encoder knob the cutting current can be regulated
between a minimum of 10A to a maximum of 33A.
Press the 'I1' switch to turn the generator off. For a few
seconds the 'D1' display will show the message 'OFF,
the led 'L1' will start flashing blue and then the
generator will be completely turned off. If the generator
needs a cooling cycle (for a maximum of 10 minutes)
the fan will continue running to then turn off
automatically.
Depending on the colours, the 'L1' and 'L2' leds show
the following generator states:
L2
Led 'L1'
Led 'L2'
D1
Blue
blinking
Green
Green
Green
Green
C1
Blue
Yellow
If a protection device triggers (alarm - Led 'L1' yellow)
the 'D1' display shows the device that has triggered:
A. 2
Overvoltage (shown the next time the generator is turned on
A. 4
after being turned off due to the device triggering)
R1
Torch button pressed while generator switching
A. 7
A1
A. 8
A. 9
A.10
Changing advanced parameters
In certain cases, the generator allows changing certain
special parameters that are shown on the 'D1' display:
AP, i.e. PILOT ARC, is the ability to set the pilot arc
current from 10A to 20A (the factory setting is 14A)
POU, i.e. POWER, the setting in KVA of the available
power form the line, whether from the mains line or
the generator, thus avoiding an overload and the
various protections triggering
Page 12
MEANING and SOLUTIONS
-
Generator being turned on or off
-
The generator is on
Indicates the presence of voltage on the
Red
torch
When the cutting current is being set it
shows when, presumably, the available
power limit will be exceeded that has
been set in the POWER menu (lower the
current value or increase the available
power value)
During cutting the available power limit
set in the POWER menu has been
exceeded (lower the current level,
increase the available power level or
shorten the length of the welding arc)
The advanced setting menu has been
Blue
selected PILOT ARC, POWER, SLEEP,
AUTO POWER OFF, Uo, FACTORY
-
Alarm
Overheating
on
Internal alarm (call the service centre)
Internal alarm (call the service centre)
Air pressure too low for cutting