Troubleshooting - Ratio RG-3600 Manual De Funcionamiento Y Mantenimiento

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

TROUBLESHOOTING

PROBLEM
Engine switch "OFF" position Turn the engine switch in "ON" position
Spark plug does not produce
Starting the
engine is
Transistor magneto does not
difficult or
impossible
compression
There are electrical
appliances connected to the
outlets
The fuse is burnt out or switch
OFF
No current
in outlet
Low performance
Appliance connected to the
faulty generator.
Voltage too
Very low performance
low (without
Condenser or AVR damaged
charge)
NOTE:
In case of any other technical problems you should contact an AUTHORIZED TECHNICAL DEALER.
Always meet local laws and regulations.
CAUSES
Lack of fuel
spark
produce spark
Leaks through
Lack of
valves
Leaks through
cylinder head
Leaks though
the spark plug
SOLUTIONS
Fill the tank
Make sure that fuel valve is open
Main fuel pump is blocked up.
Dismantle the fuel pump and clean it.
Fuel valve filter is dirty.
Remove and clean
Fuel cap air valve is blocked up.
Unblock it
Clean it or replace it
Check that spark plug/stopping cables
will not be loose or damaged.
Check that the spark plug valve cap is
well assembled on the cable.
Replace the electronic coil
Check set and grind/polish valves
Replace cylinder head
Check that the spark plug is correctly
assembled and does not cause leaks
(it is properly tight)
Unplug electrical appliances
Replace the fuse or turn the switch ON
Adjust engine rpm correctly
Get the appliance repaired.
Adjust engine rpm correctly.
Replace condenser or AVR
ENG

Hide quick links:

Tabla de contenido
loading

Este manual también es adecuado para:

Rg-6500

Tabla de contenido