Battery Type Selector Settings.
(Switch position "7" is the default factory setting).
Switch
Description
Position
0
Equalize 1
1
Equalize 2
Deep cycle
2
Lead Acid 1
Lead
3
Calcium 1
4
Gel Cell 1
5
Gel Cell 2
Lead
6
Calcium 2
AGM
7
(Default
Setting)
8
NiCad 1
9
NiCad 2
10
12 Volt
Float
Absorptio
voltage(V)
n/
Equalize
voltage
(V)
13.2
15
13.2
15.5
13.3
15
13.6
14.3
13.7
14.4
13.5
14.1
13.2
14.3
13.4
14.6
14
16
14.5
16
24 Volt
Float
Absorptio
voltage(V)
n/
Equalize
voltage
(V)
26.4
30
26.4
31
26.6
30
27.2
28.6
27.4
28.8
27
28.2
26.4
28.6
26.8
29.2
28
32
29
32
Remarks
Apply to
flooded
batteries
only
Apply to
flooded
batteries
only
OPzS
tubular plate
Sealed type
car batteries
Standard
Gel
OPzV
tubular plate
gel
Sealed type
car batteries
Standard
AGM
10 cells
resp. 20
cells
10 cells
resp. 20
cells