SET UP - Reference KEY section
1. Open unit by pressing the access panel latch (4) down while pulling the front access panel towards you.
2. Remove bag from filter and place back in unit.
3. Plug the IEC plug (10) into the power cord socket (9) on the back of the unit.
MOUNTING MAIN ASSEMBLY
1. C hoose an area to mount the unit near a standard outlet receptacle (Cord length approximately 1.6 meters).
2. U sing the mounting template, mark the wall with the 4 mounting locations. If mounting location is over an
existing stud, no preparation needed. If mounting location is over drywall only or other surface requiring
additional support, use anchors.
3. [ Anchor use only] To use anchors, drill a 10mm hole in the mounting hole location(s) and install anchors into
wall.
4. I nstall the top 2 screws leaving approximately 1/4" (6mm) from the head of the screw to the wall. Do not
install screws all the way.
5. H ang the unit on the screws installed in previous step using the top key-hole mounting holes.
6. O pen the front door of the unit and install the 2 bottom screws into the bottom mounting locations.
7. Tighten all 4 screws until flush.
8. Place the (2) provided stickers over the inside top mounting hole locations to maximize performance.
9. R emove the filter(s) from their packaging and install them in the unit Note: The "AeraMax Pro Certified Filter
Sticker" on the filter must align with the identical sticker found on the unit. If the filter is not installed properly,
the unit will not power on.
10. P lug the power cord into standard outlet receptacle.
11. Reach behind the unit on the back bottom right to access the power switch and turn unit on.
Note: Manual mode will not be available for 1 minute upon initial power-up.
6
AeraMaxPRO_AMII_230V_18L_411645_071219.indd 6-7
4
6
5
Back of Unit
7
8
9
10
4 Mounting Locations

CARE AND MAINTENANCE

CLEANING:
• Clean external housing as necessary by wiping with a dry, soft cloth; for stains, use a warm, damp cloth.
• Do not use volatile fluids such as benzene, paint thinner, scouring powder or other cleaners that may damage the unit surface.
• Clean intake and exhaust vents by wiping with a dry, soft cloth.
FILTER REPLACEMENT:
The replacement filter indicators will signal when to replace the HEPA Filter and/or Carbon filters. The replacement period will vary depending on
the hours of use, air quality, and rate of air flow. However, under normal usage, most HEPA filters need to be replaced every 1 year, Carbon filters
every 6 months, and Hybrid filters every 1 year. When a filter needs to be replaced the following color will be shown on any one of the HEPA or
CARBON filter replacement indicators:
Amber flashing = 90% filter wear (recommendation to order new filters)
Red = 100% filter wear (replace with new filters)
Do not wash and reuse any of the filters – they will not work effectively. Only use AeraMax
using any other replacements.
FILTER REPLACEMENT PROCEDURE:
1
2
1. Press the access panel latch down
2. Remove old filter(s). 3. When inserting new filters, be sure to remove the plastic bag. When inserting
while pulling front panel towards you.
the hybrid filter, make sure the green prefilter is over the black carbon side and insert that side first with
the white HEPA facing out. When inserting new Hybrid or HEPA filters, align the AeraMax
Filter stickers on the filter and the inside of the unit. The arrow should point towards the back of the unit.
Reference (5) on the KEY section.
FILTER LIGHT RESET:
When installing a new filter the unit will automatically detect the filter type but the user will have to manually reset the filter replacement indicators. To reset any
of the filter replacement indicators, press and hold filter type button that was replaced (HEPA or Carbon) until the light turns off. Repeat for other filter types as
needed. When replacing the hybrid filter, reset both the HEPA and carbon indicator lights.
TROUBLESHOOTING
PROBLEM:
POSSIBLE SOLUTION:
The air quality control system fails to start.
• Check to assure unit is connected to power supply.
• M ake sure filters are genuine AeraMax
brands. IMPORTANT: Make sure to align the AeraMax PRO Certified Stickers on the filter
and the inside of the unit. The arrows should point towards the back of the unit.
• Review Filter Replacement Method section for further detail.
• Make sure front access panel is closed completely.
• Make sure power switch is on.
The unit makes a faint ticking sound.
• This indicates that the "PlasmaTRUE™" bipolar ionizer is working.
The HEPA and/or Carbon Filter replacement indicator light
• Repeat filter light reset instruction.
remain lit after replacing the filter(s).
PRO brand replacement filters as units will not function
®
3
®
PRO Certified
®
PRO filters, as unit will not function with other
7
7/12/19 3:14 PM