Cleaning the quartz glass / Replacing the UVC lamp
Replace the UVC lamp after max. 8,000 operating hours (this corresponds to approx. one pond season with continu-
ous operation). This ensures optimum filtering performance.
C A U T I O N
Quartz glass and UVC lamp can break and cause cut injuries.
· Handle the quartz glass and UVC lamp with care.
Prerequisite
· The unit head is removed. (→ Dismantling the unit head)
· Ensure that the identification and capacity data of the UVC lamps used correspond to the information on the unit type
plate.
How to proceed:
5 L
1. Loosen the self-tapping screw until the the screw tip is sunk in the housing of the clamping screw.
2. Unscrew the clamping screw counter-clockwise.
3. Remove the quartz glass including the O ring towards the front with a slight turning movement.
4. Pull out the UVC lamp and replace.
5. Push the quartz glass including the O ring as far as the stop in the unit head.
– Clean the O ring, replace if damaged.
– Ensure that the O ring is located in the gap between the unit head and the quartz glass.
6. Tighten the clamping screw clockwise up to the stop.
7. Tighten the self-tapping screw.
8. Wipe the quartz glass tube with a damp cloth
Storage/overwintering
The unit is not frost-proof and has to be removed and put into storage if minus temperatures are expected.
How to correctly store the unit:
· Thoroughly clean the unit, check it for damage and replace any damaged parts.
· Store the unit in a dry and frost-free place.
Wear parts
· UVC lamp, quartz glass and O ring for quartz glass
Spare parts
The use of original parts from OASE ensures continued
safe and reliable operation of the unit.
Please visit our website for spare parts drawings and spare
parts.
Disposal
N O T E
Do not dispose of this unit with domestic waste.
· Render the unit unusable beforehand by cutting the cables and dispose of the unit via the return system
provided for this purpose.
Dispose of the UVC lamp by using the return system provided for this purpose.