Commissioning/start-up
N O T E
Never allow the pump to run dry. Otherwise the pump will be destroyed.
• Ensure that the pump is always flooded during operation.
• Regularly check the water level.
This is how to connect the power supply:
Only operate the unit in conjunction with the Solarsafe solar module from OASE.
The unit switches on automatically when connected to power (OASE special plug).
Prior to this observe the following operating steps: Fit the unit as an individual unit (A) or with the separate filter (B),
place the unit in a suitable position in the pond , and position the pre-filter suitably if required, then connect to the
power supply (solar modules, Solarsafe, all 12 Volt). The unit is now operational.
Installation
Aquarius Solar can be installed in two versions (A+B), unit with filter wings attached, or with filter wings removed. Fit
the water feature hose to connection (A3) which can be regulated, and the OASE spotlight to connection (A4).

Maintenance and cleaning

W A R N I N G
Possible death or severe injury from hazardous electrical voltage!
• Prior to reaching into the water, isolate (switch off and disconnect) all units/devices used in the water.
• Isolate the device (disconnect from the power supply) before carrying out any work on it.
Cleaning the device
N O T E
Recommendation regarding cleaning:
• Clean the unit as required but at least twice a year.
• When cleaning the pump, pay particular attention to the cleaning of the impeller unit and pump housing.
• Do not use aggressive cleaning agents or chemical solutions as they could attack the housing or impair the function
of the unit.
• Recommended cleaning agent for removing stubborn limescale deposits:
– Pump cleaning agent PumpClean from OASE.
– Vinegar- and chlorine-free household cleaning agent.
• After cleaning, thoroughly rinse all parts in clean water.
Malfunctions
Trouble shooting
Unit does not run
Fountain height insufficient or
inconsistent
Cause
- no voltage, 12 Volt
- Rotor blocked
- Sun energy insufficient
- Main flow regulator closed too far
- Nozzle blocked
- Filter/screen clogged
- Rotor soiled
- Hose blocked or defective
- Hose kinked
- Excessive loss due to friction in the hose
- Rotor worn
- Sun energy insufficient
Remedy
- Check voltage source
- Clean pump
- Adjust main flow regulator
- Clean nozzle
- Clean filter/screen
- Clean rotor
- Clean hose or replace
- Check hose and replace if necessary
- Reduce hose length to reduce frictional loss
- Replace rotor
- EN -