VPPM−...
12
Technical specifications
Type VPPM−...
Design
Installation position
Medium
Pressure ranges
Perm. input pressure
Control range
Overall leakage in new
condition
Connections
Nominal size
Ventilation
Exhaust
Standard nominal flow rate
Protection class
Permissible temperature
range
Ambient temperature
Medium temperature
Storage temperature
Electrical connection
Permissible operating
voltage
40
Proportional pressure regulator
As desired, preferably horizontal
(display elements facing up)
Filtered, unlubricated compressed air
(grade of filtration min. 40 m), condensation
not permitted.
2 bar type
[bar]
max. 4
0.02 ... 2
Input pressure p1 at least 1 bar above output
pressure p2
[l/h]
< 5
G1/8" (1/8 NPT)
[mm]
6
4.5
see Fig. 24
IP65 when mounted, with tightened mounting
screws, in connection with connection socket
according to Accessories".
[°C]
0 ... +60
[°C]
+10 ... +50
[°C]
10 ... +70
Crimp connector M12x1, 8−pin
[V DC] 21.6 ... 26.4 V DC (permissible residual ripple
max.: 10 %)
6 bar type
10 bar type
max. 8
max. 11
0.06 ... 6
0.1 ... 10
Festo VPPM−... 0607NH English