MODEL 1X WATER HEATER SPECIFICATIONS

Description
Electric tankless water heater that uses
Ohmic Array Technology to heat water.
The MODEL 1X Water Heater provides
reliable, controllable and immediate hot
water in conjunction with your existing
water heater.
Domestic Hot
Tank-type hot water heater booster
Water
Application
Power
30 A, 7.5 kW
Input Voltage
240 V (50/60 Hz)
Certification
UL 499
Visit our website for more information
regarding certification standards and
approvals.
Temperature
Microprocessor thermostatic
Control
temperature control adjusts
temperature 60 times per second.
Water
The water source must fall within 150 to
Conductivity
1500 µs of conductivity. The only way to
accurately check the conductivity of the
water is to use a conductivity meter. The
water company could have this
information.
Rise in Temperature
for Each MODEL 1X
Set to 30 A
For more information, please visit www.myheatworks.com.
• 1 gallon per minute demand will yield a 49° F rise in temperature
• 1.5 gallon per minute demand will yield a 33° F rise in temperature
• 2 gallon per minute demand will yield a 24° F rise in temperature
(240 V)
• 2.5 gallon per minute demand will yield a 20° F rise in temperature
Temperature
50° F to 120° F (domestic hot water use)
Output
10° C to 49° C (domestic hot water use)
Setpoint
Range
Temperature
Digital user interface, +/- 1° F or +/- 1° C
Setpoint
adjustment
Adjustment
Water
18" flexible water heater connection hoses;
Connections
3/4" or 22 mm push-fit connectors
Operating
Maximum 100 psi
Pressure
Dimensions
12.25" long by 6.5" in diameter
Weight
10.5 lbs, approximately 16 lbs installed
Digital Display
Digital LCD and push button user
interface to adjust temperature setpoint.
The digital display can be easily switched
from °F to °C.
Warranty
6-year full unit exchange warranty
Additional
No annual maintenance required.
Features
Silent when operating.