Physical
Tower (without bezel)
Height
Width
Depth
Weight (maximum configuration)
Environmental
NOTE:
For additional information about environmental measurements for specific system configurations,
contact your technical support provider.
Temperature
Operating
Storage
Relative humidity
Operating
Storage
Maximum vibration
Operating
Storage
Maximum shock
Operating
Storage
Altitude
Operating
Storage
47.89 cm (18.85 in) with feet, no casters
22.66 cm (8.92 in)
66.13 cm (26.04 in) does not include control
panel or bezel; control panel adds an additional
1.3 cm (.51 in)
49.9 kg (110 lb)
10° to 35°C (50° to 95°F)
–40° to 65°C (–40° to 149°F)
20% to 80% (noncondensing) with a maximum
humidity gradation of 10% per hour
5% to 95% (noncondensing)
0.26 G from 5–350Hz for 2 min in the Z axis
1.54 G from 10–250 Hz for 15 min in all
orientations
One shock pulse in the positive z axis (one pulse
on each side of the system) of 41 G for up to 2 ms
Six consecutively executed shock pulses in the
positive and negative x, y, and z axes (one pulse
on each side of the system) of 71 G for up to 2 ms
–16 to 3048 m (–50 to 10,000 ft)
–16 to 10,600 m (–50 to 35,000 ft)
Getting Started With Your System