Installation Instructions; Parts Included; Electrical Requirements - GE AKCQ08A Manual Del Propietario Y Instrucciones De Instalación

24” a través de la pared
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Installation Instructions

For more help, visit GEAppliances.com
BEFORE YOU BEGIN
Read these instructions completely and carefully.
IMPORTANT –
instructions for local inspector's use.
IMPORTANT –
governing codes and ordinances.
• Note to Installer – Be sure to leave these
instructions with the consumer.
• Note to Consumer – Keep these instructions for
future reference.
• Skill level – Installation of this appliance requires
basic mechanical skills.
• Completion time – Approximately 1 hour
• We recommend that two people install this
product.
• Proper installation is the responsibility of the
installer.
• Product failure due to improper installation is not
covered under the Warranty.
• You MUST use proper installation procedures as
described in these instructions when installing this
air conditioner.

ELECTRICAL REQUIREMENTS

CAUTION
Do not, under any circumstances, cut or remove
the third (ground) prong from the power cord.
Do not change the plug on the power cord of this
air conditioner.
Aluminum house wiring may present special
problems—consult a qualified electrician.
Power cord includes a current interrupter device. A
TEST and RESET button are provided on the plug
case. The device should be tested on a periodic
basis by first pressing the TEST button and then the
RESET button while plugged into the outlet. If the
TEST button does not trip or if the RESET button
will not stay engaged, discontinue use of the air
conditioner and contact a qualified service technician.
8
Save these
Observe all
IMPORTANT NOTE
For optimal energy efficiency and performance, we
recommend using the RAB24 Wall Sleeve and the
supplied stamped aluminum outdoor grille or the
RAB46B with the RAG13 stamped aluminum outdoor
grille.
For Existing Wall Sleeves
Note that the air conditioner dimensions are: 24" wide,
14" high, and 18" deep (without front). Install air
conditioner according to these Installation Instructions
to achieve the best performance. Save these Installation
Instructions for future reference.
NOTE: Do not use any screws other than those specified
here.

Parts Included

You may not need all parts in the kit. Discard unused
parts.
Name
Tapered spacer Blocks
Centering/Support Blocks
Plastic Divider
Stuffer Seal
Seal
Seal
Seal
Seal
Seal
Trim Frame (side legs)
Trim Frame (top & bottom legs)
Ground Wire (green)
Toothed Washer for grounding
screw
Grounding Screw
Grille (Plastic)
Grille (Aluminum)
Nuts (Plastic)
Screw Washer
Screw
Security Brackets for a 24" Wall
Sleeve (in a separate packet
with their 4 mounting screws)
Security Brackets for a 26" Wall
Sleeve (in a separate packet
with their 4 mounting screws)
Spec.
Qty
17" long
2
4-1/2" x 3-1/2" x 1-1/2"
4
1/8" x 4-1/2" x 14-1/2"
2
1" x 1-1/2" x 25"
1
1" x 1-1/2" x 14"
3
1" x 3/8" x 25"
2
1" x 3/8" x 14"
3
1" x 3/4" x 14"
2
2
2
2
1
2
1
1
1
4
4
4
2
2
49-5000444 Rev. 0

Capítulos

Tabla de contenido
loading

Tabla de contenido