Replacing Wireless Device Batteries

1. Remove the cover of the device from its backplate.
This creates a tamper condition on the zone.
2. Refer to the battery installation instructions on the
Installation Sheet of each component. Be sure to note
the proper orientation of the batteries as you install them.
3.
When the fresh batteries are in place, re-attach the cover to the back-plate. The
tamper is restored and the zone sends a battery trouble resto-
ral signal to the receiver. The battery trouble is now
clear and the device should function normally.
NOTE: When batteries in one device need to be replaced, the
batteries in all devices should be replaced at the same time.
Troubleshooting
1. When I enter the zone number when adding a
wireless device, the keypad gives me a long beep.
•The keypad must be properly connected to the Keybus to enter ESNs.
2. I have entered the ESN for the device but when I violate
the device, the zone does not show open on the keypad.
Check the following:
•Ensure the ESN has been entered correctly.
•Ensure that the zone is enabled for the
partition (if partition pro-gramming is used).
•Ensure that the wireless zone is not assigned to a zone used by
PC5108 modules, an on-board zone or a keypad zone.
•Ensure that the zone is programmed for something other than "Null
Operation" and that the wireless zone attribute is turned on.
3. When I try a module placement test I get no
result or "Bad" results. Check the following:
•Verify that you are testing the correct zone.
•Verify that the device is in range of the keypad. Try
testing the device in the same room as the receiver.
•Confirm that the keypad is properly connected to the Keybus. •Check
that you are testing the zone correctly. Refer to the instruc-
tions that came with the device.
•Check that the batteries are working and installed correctly.
•Look for large metal objects that may be preventing
the signal from reaching the keypad.
•The device must be located where consistent "Good" results are
obtained. If several devices show "Bad" results, or if panic pendants
and wireless keys operate inconsistently, move the receiver.
4. The LED on the motion detector does not
turn on when I walk in front of the unit.
•The LED is for walk test purposes only. See your WS4904P-433/
WS4904P(L)-433 instruction sheet for walk test instructions.