Installation Instructions; Disassemble Keypad - DSC PowerSeries PK5500 Instrucciones De Instalación

Ocultar thumbs Ver también para PowerSeries PK5500:
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

English

Installation Instructions

The PK55XX\RFK55XX keypads can be used on security systems
with up to 64 zones. These keypads are compatible with the latest
version of the folllowing DSC security
systems:
•PC580
•PC585
•PC1555MX
•PC1616 •PC1832 •PC1864
•PC5008 •PC5010 •PC5015 •PC5016
•PC5020
The RFK55XX keypads combine a wireless
receiver with the respective PK55XX keypad.
Specifications
• Temperature range: -10°C to +55°C (14°F to 131°F), Temperature
range for UL/ULC: 0°C to +49°C (32°F to 120°F)
• Humidity (MAX): 93%R.H.
• Plastic enclosure protection degree: IP30, IK04
• Voltage rating: 12V
nominal
DC
• Connects to control panel via 4-wire Keybus
• 1 keypad zone input/PGM output*
• PK55XX Current draw: 50mA (standby)/125mA (maximum)
• RFK55XX Current draw: 75mA (standby)/135mA (maximum)
• Wall mount tamper
• 5 programmable function keys
• Ready (Green LED), Armed (Red LED),
Trouble (Yellow LED), AC (Green LED)
• Low temperature sensor
• Frequency: 433.92MHz (RFK55XX-433)
• Up to 32 wireless zones (RFK5500 Only)
• Up to 64 wireless zones (RFK5564 and Power v4.6+Only)
*Zone not to be programmed as Fire type or 24h type.
Unpacking
The Power keypad package includes the following parts:
•One Power keypad
•Keypad inner door labels
•Four mounting screws
switch
•2 end-of-line resistors
•Installation Instructions
Mounting
You should mount the keypad where it is accessible to designated
points of entry and exit. Once you have selected a dry and secure
loca-tion, perform the following steps to mount the keypad.

Disassemble Keypad

1. Insert a flat head screwdriver into the provided slot (first of two).
2. Move screwdriver toward the back plastic and lift as in the
below dia-gram. This will unhook one side of the front plastic.
3. Repeat step # 1 and 2 on the second provided slot to
disconnect the front plastic and allow access for wiring.
•PC1565
•PC5005
Mount and Wire Keypad
Knock Out
Wiring Slot
Knock Out
Hooks
•1 tamper
3
1
2
Knock Out
Tamper
1.
2.
Hooks
3.
4.
Tamper
1. Secure Keypad to wall using mounting holes. Use all 4
screws provided unless mounting on a single gang box.
2. Place keypad into hooks on the backplate and swing down to engage.
3. Run wire through wiring slot or knockouts. Connect Keybus and PGM/Zone wiring
to keypad. Place tamper switch into tamper hole on backplate.
4. Remove keypad from hooks. Place keypad into backplate, ensure the
wire is pushed back into the wall as much as possible. Route the wire
inside the keypad ensuring high components are avoided. Snap the
front assembly closed, ensuring that there is no pressure to the keypad
from the wire below.
NOTE: If any tension is found between the front keypad assembly and wir-
ing, please open the keypad, reroute the wire and close again. Repeat
these steps until the keypad is closed
properly.
Wiring
1. Before wiring the unit, ensure that all
power (AC transformer and battery) is dis-
connected from the control panel.
2. Connect the four Keybus wires from the con-trol
panel (red, black, yellow and green) to
the keypad terminals. Refer to diagram: 3. If
programmed as an input, you can con-nect a
device - such as a door contact - to
the 'P/Z' terminal of the keypad. This eliminates the need to run wires back to the
control panel for the device. To connect the zone, run one wire from the device to
the 'P/Z' terminal and the other wire from the device to the B (black) terminal. For
powered devices, run the red wire to the R (positive) terminal and the black wire
to the B (negative) terminal. When using end of line supervision, connect the zone
according to one of the configurations outlined in your system's Installation
Manual.
4. If the 'P/Z' terminal is programmed as an output, the output follows the
PGM programmed in Section [080]. A small relay, buzzer or other DC
Swing
to engage
Press to Snap
PK55XX/RFK5
5XX
R
ED
B
LK
Y
GRN
EL
To
zone
or
PGM output
Tabla de contenido
loading

Este manual también es adecuado para:

Powerseries rfk5500Powerseries rfk5564

Tabla de contenido