Connection box (REF 3495EURO) (not provided)
• Connect the projector's flexible conduit to the 3/4'' outlet located on the bottom of the connection box ensuring that there
is a waterproof seal.
• Use the connector blocks provided with the junction box to connect the spotlight to the power supply by twisting the wires
and ensuring that the terminal screws are well tightened.
Transformer power
The transformer to be used must have a secondary voltage of 12V (12.5V depending on the model). The power must
be suitable for the power of the spotlight(s) to be connected.
In all cases, the total power of the spotlights must be less than or equal to the power of the transformer.
Each spotlight requires individual protection. Protection must be provided for the transformer secondary winding using 2A
or 5A fuses or circuit breakers (see wiring diagram below).
Example with 2
spotlights
Page 4 of 5
230V
12V
2A protection
Spotlight 1
Spotlight 2
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
2A protection
LED Lights
L
N
230V
Example with 1
spotlight
12V
2A protection
Spotlight 1
Rev. A